Ingersoll-Rand ARO 637140-4B Operator'S Manual Download Page 1

INGERSOLL RAND COMPANY LTD

209 NORTH MAIN STREET – BRYAN, OHIO 43506

 (800) 495-0276

 FAX (800) 892-6276 

© 2020 

CCN 15331259

arozone.com

OPERATOR’S MANUAL 

670093

INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE

RELEASED: 7-7-09

REVISED: 5-29-20

(REV: J)

1/2” DIAPHRAGM PUMP

1:1 RATIO (NON-METALLIC)

READ THIS MANUAL CAREFULLY BEFORE INSTALLING, 

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

670109

SERVICE KITS

Refer to Model Description Chart to match the pump material 

options.

637140-4B

 for fluid section repair (see page 4).

637428

 for air section repair (see page 6).

PUMP DATA

Model.  . . . . . . .

 670093, 670109

Pump Type  . . .  

Non-Metallic Air Operated Double Diaphragm

Material   . . . . . 

see Model Description Chart

Weight . . . . . . . 

Polypropylene. . . . 7.2 (3.3 kgs)

Maximum Air Inlet Pressure  . . . . . . . .  

100 psig (6.9 bar)

Maximum Material Inlet Pressure . . .  

10 psig (0.69 bar)

Maximum Outlet Pressure . . . . . . . . . .  

100 psig (0.69 bar)

Displacement / Cycle @ 100 psig.   . . .  

0.040 gallons (0.15 L)

Air Consumption  . . . . . . . . . . . . . . . . . . . . . . 

1 cfm / gallon (approx.)

Maximum Flow rate        

(Ball). . . . . . . . . . 13 gpm (49.2 lpm)

Maximum Particle size  

(Ball). . . . . . . . . . 3/32” dia. (2.4 mm)

Maximum Temperature Limits

  E.P.R. / EPDM . .   . . . . . . . . . . . . .  -60

 to 280

 F (-51

 to 138

 C)

  Groundable Acetal . .  . . . . . . . .  -20

 to 180

 F (-29

 to 82

 C)

 Hytrel

  . . . . . . . . . . . . . . . . . . . . .   -20

 to 180

 F (-29

 to 82

 C)

  Neoprene . .   . . . . . . . . . . . . . . . .  0

 to 200

 F (-18

 to 93

 C)

 Nitrile   . . . . . . . . . . . . . . . . . . . . . . 10

 to 180

 F (-12

 to 82

 C)

 Polypropylene  . . . . . . . . . . . . . . 32

 to 175

 F (0

 to 79

 C)

 Polyurethane  . . . . . . . . . . . . . . . -10

 to 150

 F (-23

 to 66

 C)

  Kynar PVDF

. . . . . . . . . . . . . . . .  10

 to 200

 F (-12

 to 93

 C) 

Santoprene

  . . . . . . . . . . . . . . .  -40

 to 225

 F (-40

 to 107

 C)

 PTFE . . . . . . . . . . . . . . . . . . . . . . . . 40

 to 225

 F (4

 to 107

 C)

 Viton

  . . . . . . . . . . . . . . . . . . . . . . -40

 to 350

 F (-40

 to 170

 C)

Dimensional Data . . . . . . . . . . . . . . . .  

see page 8

Figure 1

Summary of Contents for ARO 637140-4B

Page 1: ...del 670093 670109 PumpType Non Metallic Air Operated Double Diaphragm Material see Model Description Chart Weight Polypropylene 7 2 3 3 kgs Maximum Air Inlet Pressure 100 psig 6 9 bar Maximum Material...

Page 2: ...ing out let hose or piping from pump WARNING HAZARDOUS MATERIALS Can cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous ma...

Page 3: ...d of time y Disconnect the air supply from the pump if it is to be inactive for a few hours y The outlet material volume is governed not only by the air supply but also by the material supply availabl...

Page 4: ...4 93100 4 T 26 Bolt 5 16 16 x 1 1 2 16 93109 SS 29 Set Screw for model 670093 2 Y29 132 S SS for model 670109 33 O Ring 1 3 16 OD 4 93762 E 34 Manifold Outlet top 2 93102 1 P 35 Manifold Foot bottom 2...

Page 5: ...NTS NOTE DO NOT OVERTIGHTEN FASTENERS 6 Diaphragm nut 95 105 in lbs 10 7 11 9 Nm 62 Fluid cap manifold nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in 39 Nuts 2...

Page 6: ...UID SECTION DISASSEMBLY 1 Remove 34 top manifold 36 swivel assembly 2 Remove 19 O rings 21 seats and 22 balls 3 Remove 35 bottom manifolds 36 swivel assembly 4 Remove 19 O rings 21 seats and 22 balls...

Page 7: ...ly Lubriplate 94276 to all O rings U cups and mating parts 135 174 134 144 Position Sensor when pump is completely assembled Screw Sensor 233 into Exhaust Cover 129 until it contacts Ring 2 Backout 1...

Page 8: ...al position so that the balls will check by gravity y Check for pump cavitation suction pipe should be sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosit...

Page 9: ...stem Valve will not run when pump does not cycle Supply air Air pilot return solenoid actuated 4 way valve PLC Controller signal Pneumatic feedback signal from pump TYPICAL BASIC REMOTE HOOK UP 10 32...

Page 10: ...nal from pump Pneumaticecho can be used to interrupt the PLC signal and set alarm NOTE Pump may not be short stroked with this system Pneumatic to electric signal can send alarm to operating system LE...

Page 11: ...670093 en Page 11 of 12 NOTES...

Page 12: ...Page 12 of 12 670093 en PN 97999 1471...

Reviews: