Nix Product Manual |
Wiring and Connections
INGENIA | 01/22/2019
105
•
General purpose digital input 1 (GPI1) for Direction.
Examples of dual input mode PWM command in differential and single ended connections are shown in the next
figures.
7.6.6 Encoder following or electronic gearing
Encoder following command source is used tor
drive two motors to the same position
. The encoder (or an
auxiliary encoder) of the master motor is read by the Nix Servo Drive and used as position target. A gearing ratio
between the motors (input counts to output counts ratio) can be configured via software.