1 2 . T E C H N I C A L S P E C I F I C A T I O N S
X4 RM PLUS
600
X4 RM PLUS
800
X4 RM PLUS
1000
X4 RM PLUS
2000
X4 RM PLUS
3000
GENERAL CHARACTERISTICS
Technology
Line Interactive
Power
600VA
800VA
1k VA
2k VA
3k VA
Power factor
0,6
0,6
0,6
0,6
0,6
Protected UPS outlets - IEC
4
4
8
8
8
Protected UPS outlets – FR/SCHUKO (type
CEE 7/7)
2
2
2
2
2
Tel/ADSL line protection
RJ45 (1-IN/1-OUT)
PROTECTION & FILTERING
Output form
Simulated Sine Wave
Protection
Discharge / overcharge / overload
Input protection
Fuse
Disjoncteur
PHYSICAL CHARACTERISTICS
Dimensions -
DxWxH (mm)
230 x 438 x 86
300 x 438 x 86
460 x 438 x 86
Net weight
kg
6,5
7,7
11,3
14,4
23,6
INPUT TECHNICAL CHARACTERISTICS
Voltage
220 VAC
Voltage range
162-268 VAC
Frequency
50 Hz or 60 Hz (auto sensing)
OUPUT TECHNICAL CHARACTERISTICS (battery mode)
Voltage
220 VAC
Automatice voltage regulation
± 10 %
Frequency
50 Hz ± 1 Hz
Crest ratio
3:1
BATTERY
Battery charger
Operates when the UPS is connected to mains
Cold start (no mains)
Yes
Batteries type & number
12V/7AH*1
12V/9AH*1
12V/7AH*2
12V/9AH*2
12V/7AH*4
Recharging voltage
13.7+/-0.5V
13.7+/-0.5V
27.4±1V
54.8V±1.5V
Recharging time
4-6 hours to 90% after complete discharge
Backup time (1 PC load)
10min
15 min
30min
50min
65min
INDICATORS
Indicators
Digital Display Panel : AC Mode, Battery Mode, Load Level, Battery Level, Input
Voltage, Output Voltage, Overload, Fault, and Low Battery
AUDIBLE ALARMS
Battery mode
Sounding every 10 seconds
Low battery
Sounding every second
Overload
Sounding twice every second
Default
Continusly sounding
COMMUNICATION
Communication port
USB
Logiciel
Infopower software
ENVIRONMENT
Ideal environment
0-40°C, 0-90% of relative humidity (without condensation)
Noise level
<40dB
<45dB
NORMS
Standard
CE RoHS
EMC (Electromagnetic compatibility)
EN62040-2:2006, EN61000-4-2:2009, EN61000-4-3:2006+A1:2008+A2:2010,
EN61000-4-4:2004+A1:2010, EN61000-4-5:2006, EN61000-2-2:2002
Low voltage (Safety)
EN60950-1:2006+A11:2009+A1:2010, EN62040-1:2008
SALES INFO
Warranty
2 years
Gencods
3700085
66061 4
3700085
66062 1
3700085
66063 8
3700085
66064 5
3700085
66065 2