2-24
Chapter 2: Hardware installation
2.3.6 Management console connections
To connect you main storage to external consoles, you need the following:
•
DB 9 female to mini-USB cable (bundled with the package)
•
CAT 5e LAN cable (user supplied)
Connecting main storage to external consoles
See below table for the list of default values of the serial port.
Baud rate
115200
Data bit
8
Parity
None
Stop bit
1
Flow control
Hardware
IMPORTANT!
Always connect to the primary controller (controller A).
NOTES:
• A null modem may be required if you are using a third-party cable.
•
For TCP/IP connection and firewall configuration, refer to EonOne, your management software’s
online help, or user manual. If your network is not running the DHCP server protocols, you can use
the default IP
10.10.1.1
if you are accessing for the first time.