background image

Reference Manual 

Solaira Cosy 

XL Double

 

 

CANADA & USA MODEL HEATERS: 

SCOSYXL230120 / L1   (120V - 1500W (TOTAL: 3000W)) 
SCOSYXL230240 / L1   (208 / 240V - 1125 / 1500W (TOTAL: 2250 / 3000W)) 
SCOSYXL240240 / L1   (208 / 240V - 1500 / 2000W (TOTAL: 3000 / 4000W))

 

WEATHERPROOF INFRARED HEATERS 

SUITABLE FOR OUTDOOR AND INDOOR USE - 

RESIDENTIAL, COMMERCIAL AND INDUSTRIAL 

INFORESIGHT CONSUMER PRODUCTS INC.

 

125 Traders Blvd. E Unit # 4, Mississauga, Ontario L4Z 2H3 

Tel: 905-568-7655  -  Fax: 905-568-7521 

Email: [email protected]  -  Website: www.solairaheaters.com 

247748 

I M P O R TA N T   -   S AV E   T H E S E   I N S T R U C T I O N S   F O R   F U T U R E   R E F E R E N C E  

CANDEL EMITTER RANGE 

E

N

 

Summary of Contents for SCOSYXL230120

Page 1: ...0W TOTAL 3000 4000W WEATHERPROOF INFRARED HEATERS SUITABLE FOR OUTDOOR AND INDOOR USE RESIDENTIAL COMMERCIAL AND INDUSTRIAL INFORESIGHT CONSUMER PRODUCTS INC 125 Traders Blvd E Unit 4 Mississauga Onta...

Page 2: ...olt heater when not in use or if hard wired disconnect the supply 6 Do not operate any heater with a damaged cord or after the heater malfunctions has been dropped or damaged in any manner Return heat...

Page 3: ...reas where gasoline paint or flammable liquids are used or stored 14 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire 15 Do not cover or otherwise ob...

Page 4: ...ed 5 WARNING Keep the mains cords away from the body of the heater which will get hot during use 6 If a socket outlet is used do not position the outlet immediately behind the heater 7 Avoid the use o...

Page 5: ...RISK OF FIRE WARNING RISK OF FIRE SPECIFICATION T a b l e 1 C a n a d a a n d U S A H e a t e r s INSTALL ATION The 120V version of the heater is fitted with 2 supply cords measuring 180 inches 500 c...

Page 6: ...dy or obstructing the air vents HORIZONTAL MOUNTING Fig A Fig B Fig C MIN 45 98 in 250 cm GROUND LEVEL INDENT PREVENTS DROP DOWN MOVEMENT CAUTION CAUTION CAUTION CAUTION MOUNTING Switch off unplug the...

Page 7: ...ntact your local distributor quoting model type and rating from rating label It is very important that your replacement emitter is exactly the same as the one it was supplied with Failure to fit the e...

Page 8: ...the emitter Contact your distributor for the correct replacement quoting model type and rating from rating label We recommend you read through the procedure and refer to the parts diagram on the back...

Page 9: ...emitter the wire will be clearly visible in the emitter wire tube so gently pull the wire Fig 6 out of the tube until it is free 10 One at a time pull the spring clips back in the direction shown in F...

Page 10: ...2H3 Tel 905 568 7655 Fax 905 568 7521 Email info solairaheaters com Website www solairaheaters com Due to our policy of ongoing improvement we reserve the right to make changes without notice 2013 IN...