background image

   

13 

 

 

6th Floor of Block A, Changbai Technology Park, No.8 

Zhenzhu RD, Xinzhan General Pilot Zone 

China, Anhui, Hefei

230012 

0551-6282982 

 

Fig. 6-5 Compass calibration interface 

6.8 Image Calibration (Only for Attachment) 

When Xclip is installed on the white light sighting tool as an infrared extension 

component, if the cross division of the white light sighting is not in the center of the 

infrared image, the image calibration function can be used to shift the infrared image 

to ensure the position consistency between the white light image and the infrared 

image. 

 

Fig. 6-6 Image calibration interface 

Operation:

 

 

In  normal  display  mode,  press  the 

M  (13)

  button  and 

C  (14)

  button  for  3s  at 

the same time to enter the image calibration interface (fig. 6-6).   

Summary of Contents for Xclip

Page 1: ...Xclip Thermal Imaging Attachment User Manual InfiRay Technologies Co Ltd ...

Page 2: ...f 8 6 2 Standby Mode 8 6 3 Status bar 8 6 4 Shortcut Menu 8 6 5 Advanced Menu 9 6 6 Blind Pixel Calibration 11 6 7 Compass Calibration 12 6 8 Image Calibration Only for Attachment 13 6 9 Stadiametric Rangefinder Only for Monocular 14 7 Preventative Maintenance 15 7 1 Battery Installation 15 7 2 Product Cleaning and Maintenance 16 7 3 Safety Regulation 16 8 General Trouble Shooting 17 9 Appendix 18...

Page 3: ...fferent from the night vision device based on image enhancement Xclip doesn t need external light source and isn t influenced by strong light exposure It can be used in the night or bad weather conditions such as fog rain smog and can detect the objects through obstacles such as branch tall grass dense bushes and so on Xclip has a wide range application including night hunting observation and terr...

Page 4: ...ular Eyepiece Locking Ring Fixing the monocular eyepiece on Xclip unit Eyepiece Adjustment Adjusting the diopter of monocular eyepiece to suit different eyesight Eye Shade Attachment s Eyepiece Eyepiece as the infrared expansion attachment of white light sight Clamping Ring for Adapter Ring Used to lock the adapter ring between the white light sight and the attachment Locking Ring of Attachment s ...

Page 5: ...on Save and exit menu C 14 Button Shutter correction Background correction C 14 Button Adjust parameter Scroll down options M 13 Button C 14 Button Attachment Enter image calibration interface Power 12 Button Up Left shift Up Left quick shift M 13 Button X Y shift Save and exit C 14 Button Down Right shift Down Right quick shift Monocular Enter stadiametric rangefinder interface Power 12 Button In...

Page 6: ...Screen lightness setup four levels Image mode B Black hot W White hot R Red hot C Pseudo Color E zoom Only for Monocular 1 2 4 Ultraclear mode Bluetooth option Bluetooth on Bluetooth connected Video out option Video out on Battery type selection Blind pixel correction option Factory reset Battery capacity indicator Type C power supply Orientation shift ...

Page 7: ... 50mk Frame Rate 50Hz Optics Parameters Objective Lens 42mm Field of View 8 9 6 7 Magnification Attachment 1 Monocular 2 9 11 6 Diopter Adjustment 5D 5D Detection Range Target size 1 7m 1 2m Detection 2100m 2 pixels Recognition 700m 6 pixels Display Type OLED Resolution 1024 768 Electrical Parameters Battery CR123 2 Power Consumption 1500mW Max Battery Life 4hr External Interface USB Interface Typ...

Page 8: ...thout batteries 420g Dimension 154mm 61mm 58mm Adapter Ring M52 0 75 5 System Function Quick conversion between attachment and monocular Quick mounting and removal of attachment Detection range above 1 5km 1024 768 high resolution OLED display Bluetooth remote control Four image modes white hot black hot red hot pseudo color Monocular digital zoom 1 2 4 Type C interface power supply and data trans...

Page 9: ...ng the Power 12 button for power saving 6 3 Status bar The status bar is located at the bottom of the screen which shows information such as image mode screen lightness level bluetooth activated E zoom video out activated battery status 6 4 Shortcut Menu In the normal display mode short press M 13 button to switch the order of no menu screen brightness image mode electronic zoom exit shortcut menu...

Page 10: ...From top to bottom the six function options are Ultraclear mode Bluetooth video out buttery type blind pixel correction factory reset referring to table 6 1 for details Operations Under the advanced menu short press M 13 button to adjust the parameters of present option or enter the secondary menu Power 12 button is used to shift up or left C 14 button is used to shift down or right Long pressing ...

Page 11: ...is enhanced which is suitable for cloudy rainy foggy and other harsh weather conditions The icon displays on the status bar Bluetooth ON OFF When Bluetooth is on it can be operated with the bluetooth remote control or mobile phone APP please search for connection by mobile phone within 1 minute otherwise the bluetooth will be automatically turned off The icon displays on the status bar Video Outpu...

Page 12: ...d element calibration option and press M 5 button to enter the blind pixel correction interface fig 6 3 A cross cursor will appear in the center of the screen And then move the cursor up down or left right to select the blind pixel through the Power 4 button and C 6 button And press M 5 button to switch the orientation of X axis left right and Y axis up down After selecting the blind pixel press P...

Page 13: ... 360 3 laps around the optical axis to enter the compass calibration interface rotate direction as shown in fig 6 4 Fig 6 4 Rotate direction And then that a three axis coordinate system shown as fig 6 5 will appear in the center of the screen ten plane calibration method is used to rotate Xclip It will automatically exit and complete compass calibration after 30s During the calibration process sho...

Page 14: ... as an infrared extension component if the cross division of the white light sighting is not in the center of the infrared image the image calibration function can be used to shift the infrared image to ensure the position consistency between the white light image and the infrared image Fig 6 6 Image calibration interface Operation In normal display mode press the M 13 button and C 14 button for 3...

Page 15: ...bration interface 6 9 Stadiametric Rangefinder Only for Monocular Stadiametric rangefinder is only for monocular mode which allows the user to estimate approximate distance to an object of known size Fig 6 7 Stadiametric rangefinder interface In normal display mode press the M 13 button and C 14 button for 3s at the same time to enter the stadiametric rangefinder interface fig 6 7 You will see on ...

Page 16: ...yed on the status bar and there are four levels of power When the icon is appeared on the status bar please change the battery in time so as not to affect the use It is necessary to power off before replacing the batteries Turn the battery compartment knob 4 counterclockwise until stop and remove it Install two CR123 batteries according to electrode instructions on the label inside the battery com...

Page 17: ...s The product body can be scrubbed with soft cloth dipping certain amount of alcohol For optical glass devices such as eyepiece lens and objective lens dust should be blown first and then use charcoal pen or fat free cotton dipping non methylated alcohol to wipe slightly 7 3 Safety Regulation Please use batteries regularly Do not throw the batteries away or put them into fire after use Please use ...

Page 18: ...pen Open analog video output Data cable doesn t support data transmission Replace data cable Fail to start up Wrong battery installation or low power Check the battery installation and battery power Insufficient external supply voltage Check the voltage of external power supply The attachment s eyepiece is stuck during installation Eye relief mounting limit block isn t placed parallel to the guide...

Page 19: ...t cannot be ruled out Private demolition is strictly prohibited 9 Appendix 9 1 User Interface Description Custom interface and data cable are adopted to support type c power supply serial port and PAL video Support type c and battery power supply support over voltage and under voltage reverse connection protection 9 2 Product Dimensions 9 2 1 Boundary Dimension ...

Page 20: ...19 6th Floor of Block A Changbai Technology Park No 8 Zhenzhu RD Xinzhan General Pilot Zone China Anhui Hefei 230012 0551 6282982 9 2 2 Bottom Mounting Hole Size ...

Reviews: