6 Maintenance 

6.1 Attention 

 

Make  sure  the  camera  is  fixed  firmly  when  the  camera  is  installed  on  wall, 
ceiling or pillar.   

 

The  camera  shall  not  fall  on  the  equipment,  especially  vigorous  vibration 
equipment.  Keep  the  camera  away  from  the  presence  of  magnetic  field 
interference, avoid mounting camera to the surface where occurs vibration or 
shocks easily. (The camera may be damaged ignoring this item). 

 

The camera lens shall not be aimed at the high temperature target such as sun, 
incandescent light etc., or it may damage the lens or detector.   

 

Equipment used indoors should not be installed  exposed to  rain  or very  wet 
areas. 

 

Do not place the equipment in an environment with corrosive gas, which may 
cause damage to the equipment. 

 

Avoid  placing  equipment  in  the  area  where  has  direct  sunlight,  poor 
ventilation, or near heat sources such as heaters (ignoring this can lead to fire 
hazards). 

 

Please keep all original packing materials of the equipment properly, so that in 
case of any problem, use packing materials to pack the equipment and send it 
to the agent or return it to the manufacturer for treatment. IRay shall not be 
responsible for any accidental damage in transit caused by materials other than 
the original packaging. 

6.2 Cleaning and Maintenance 

 

Do not use cleaning products that corrode or scratch optical glass components. 

Summary of Contents for ITSII 300

Page 1: ...ITS 300 AI Thermal Imaging Temperature Screening System Quick User Guide V1 0 1 Yantai IRay Technology Co Ltd...

Page 2: ...is used as a guide The photos graphics diagrams and illustrations provided in the manual are only used to explain which may be different from the specific product Please refer to the real object We t...

Page 3: ...d Connecting Camera 5 3 3 Blackbody Specification and Installation 7 3 4 Site Layout Solution 8 3 5 Site Installation and Layout Considerations 9 3 6 Parameter Setting Guidance 10 4 Software User Guid...

Page 4: ...g System developed for the epidemic situation The system combines high precision thermal temperature measurement and accurate face recognition technology which can quickly detect pedestrians of abnorm...

Page 5: ...2 1mrad Visual Imaging Resolution 1920 1080 Focal length 4 7 141mm HFOV 60 5 2 3 Temperature Measurement Measurement range 0 60 Accuracy 1 0 3 target temperature of 33 42 ambient temperature of 16 32...

Page 6: ...nalysis 1TB historical data storage retrieve in face mask alarm time Body temperature correction Intelligent human body temperature correction Flux 200 People minute Remote access Support web remote a...

Page 7: ...ry List Before installation please make sure that the equipment in the package is intact and all parts are available Optional package Prepared by users Displayer resolution 1920 1080 HDMI cable Tools...

Page 8: ...p of the product for fixing the camera to the adapter or bracket Figure 3 1 Structure of Camera Take the thermal camera mounted on a tripod as an example as follows Remove the tripod head counterclock...

Page 9: ...amera height according to the deployment scenario 1 7m 2m is appropriate Figure3 3 Camera Installation Connect the DC 12V power cable and network cable to the DC in port and RJ45 port of camera Figure...

Page 10: ...ment temperature 0 40 Temperature range Ambient temperature 5 50 Temperature resolution 0 1 Accuracy 0 2 35 Emissivity 0 97 0 02 Settling time 5min Temperature stability 0 1 0 3 h Effective radiant su...

Page 11: ...height and distance of infrared measurement thermal imaging camera and external reference blackbody are determined according to the specific application scene and specific model but the following pri...

Page 12: ...area of the camera market and shall not be shielded by pedestrians Figure 9 Infrared Imaging on PC Environmental requirements The infrared temperature measuring camera is arranged in an environment w...

Page 13: ...om with a constant temperature from a hot cold outdoor environment at this time a long enough channel needs to be reserved to allow the subject s body surface temperature to gradually stabilize before...

Page 14: ...etwork cardd1 192 168 1 124 Network card2 192 168 1 125 4 2 System Login There are two ways to login ITS II system one is login local server via GUI and another is login Web server via Explorer Figure...

Page 15: ...ccess Server or else it will warning login error 5 Troubles Shooting Troubles Shooting Fault description Possible Causes Method of exclusion Boot failure Power connector is loose Check whether the pow...

Page 16: ...ent light etc or it may damage the lens or detector Equipment used indoors should not be installed exposed to rain or very wet areas Do not place the equipment in an environment with corrosive gas whi...

Page 17: ...not squeeze the lens surface wipe liquid also can not dip in too much make sure the cloth is wet but wipe liquid can not be extruded If still not clean replace the cloth and repeat operation 6 3 Safe...

Page 18: ...V1 0 1 15 Yantai IRay Technology Co Ltd 11th Guiyang Street YEDA Yantai 264006 P R China Fax 86 0535 3410610 Email sales IRaytek com Address 11th Guiyang Street YEDA Yantai Shandong Province...

Reviews: