Infinova V1691 Series Installation & Operation Instructions Download Page 1

 

 

 
 
 
 

 

 

V1691 Series 

Outdoor/Indoor Receiver/Drivers 
Installation/Operation Instructions 

 

 

 

 

 

This manual applies to below series products

 

V1691/V1691X/V1691-24A/V1691E/ 
V1691EX/V1691E-24A 

 

 

 

 

 

 

This manual describes the installation and operation procedures for V1691 Series Receiver/drivers. Compatible 
with all Infinova series matrix switching systems, V1691 Series Receiver/drivers are designed to perform PTZ, 
lens zoom in/out, focus, iris, and auxiliary functions at a camera site. A unique camera ID is assigned to each 
receiver/driver, so the operators could only control the selected camera through the corresponding receiver/driver. 
V1691 Series Receiver/drivers are classified as a single-channel type since one unit controls only one camera at a 
site. 

Summary of Contents for V1691 Series

Page 1: ...rivers Compatible with all Infinova series matrix switching systems V1691 Series Receiver drivers are designed to perform PTZ lens zoom in out focus iris and auxiliary functions at a camera site A unique camera ID is assigned to each receiver driver so the operators could only control the selected camera through the corresponding receiver driver V1691 Series Receiver drivers are classified as a si...

Page 2: ......

Page 3: ...iver drivers all comply with Part 15 of the FCC rules Operation is subject to the following two conditions z This device may not cause harmful interference z This device must accept any interference received including interference that may cause undesired operation V1691 Series Receiver drivers have been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of t...

Page 4: ...mmended by manufacturer z Position power source and related wires to assure they will be kept away from ground and access way z Refer all service matters to qualified personnel z Save product packaging to ensure availability of proper shipping containers for future transportation Indicates that the un insulated components within the product may carry a voltage harmful to humans Indicates operation...

Page 5: ...00 3 3 2 2 DIP Switch SW201 4 3 2 3 Lens Voltage Adjustment 4 3 2 4 Jumper Setting 4 3 2 5 Presets 5 Chapter IV Operation 6 4 1 Preparation 6 4 2 Powering On 6 4 3 Pan Tilt Lens Control 6 Appendix I Camera Site ID DIP Switch Settings 6 Appendix II System Testing 9 Appendix III Specifications 10 Appendix IV Typical System Connections 11 1 Connect V2011 to V1691 11 2 Connect V2015 to V1691 12 3 Conn...

Page 6: ......

Page 7: ... tilt lens and auxiliaries operation V1691X For indoor application Manchester RS485 receiver driver 230VAC 50Hz input 14VDC 24VAC output for camera power and pan tilt operation V1691 24A For indoor application Manchester RS485 receiver driver 24VAC input 14VDC 24VAC output for camera power pan tilt lens and auxiliaries operation V1691E For outdoor application Manchester RS485 receiver driver 120VA...

Page 8: ...as an example to show system connections and setup in this chapter Unless specially noted the descriptions illustrated for V1691 apply to all V1691 series receiver drivers 3 1 1 Code Source to V1691 Series receiver drivers V1691 control line connector J202 is a 3 position terminal labeled B R W R and S G on the side panel of the unit and a mating 3 position screw terminal plug is supplied Note The...

Page 9: ... Pan Tilt Wiring 1 Check the power supply cable to make sure the power is off 2 Locate the Pan Tilt and Lens connector on the side of the receiver driver near the power cord 3 Insert the Pan Right wire of the Pan Tilt unit into the pin location for Pan Right 4 Insert the Pan Left wire of the Pan Tilt unit into the pin location for Pan Left 5 Insert the Tilt Up wire of the Pan Tilt unit into the pi...

Page 10: ... Ⅱ 3 2 3 Lens Voltage Adjustment V1691 is adjustable for a range of camera Lens servo voltages The lens output voltage can be adjusted through the selection switch R114 on V1691 PCB The voltage range is from 6V to 14V and the default voltage is 10V 3 2 4 Jumper Setting Note The PCB edge is in the left of the jumper switch Terminator Setting Terminator jumper Manchester J200 RS485 J203 J200 J203 Co...

Page 11: ...cher Receiver Figure 3 8 Manchester Connection Method 3 2 5 Presets Address Baud rate bps Presets Protocol V2116 V2116 V2011 V2116 V2116 V2011 V2116 V2116 V2011 Manchester 1 64 1 72 1 72 Pelco P 1 255 1200 19200 2400 9600 1 64 1 64 Pelco D 1 255 1200 19200 2400 1 64 1 32 Infinova 1 128 1200 19200 2400 19200 1 64 1 60 Samsung 1 254 1 32 1200 19200 4800 38400 1 64 1 64 ...

Page 12: ... on the V1691 panel illuminates when the unit is powered on If the LED does not illuminate it indicates that there might be loose power connection or something wrong with the receiver The green LED labeled CODE on the V1691 panel illuminates when the unit is receiving valid code The LED turns off immediately after the code disappears If this LED does not illuminate there might be something wrong w...

Page 13: ...7 1 ON 0 OFF ...

Page 14: ...8 1 ON 0 OFF The CAM address ranges from 1 to 255 for PELCO P D from 1 to 128 for Infinova protocol from 1 to 254 for SAMSUNG and from 1 to 64 for Manchester protocol ...

Page 15: ... 1 2 3 4 5 6 7 8 Up 1 0 0 0 Down 0 1 0 0 Left 1 1 0 0 Right 0 0 1 0 Left up 1 0 1 0 Left down 0 1 1 0 Right up 1 1 1 0 Right down 0 0 0 1 FAR 1 0 0 Focus NEAR 0 1 0 CLOSE 1 1 0 Iris OPEN 0 0 1 WIDE 1 0 1 Zoom TELE 0 1 1 ON 1 AUX OFF 0 Note indicates 0 or 1 ...

Page 16: ... 24VAC 14VDC Power Requirements 5W With camera load 14W Mechanical Dimensions W H D V1691 7 3 3 7 11 4 185 mm 95 mm 290 mm V1691E 12 0 3 3 8 0 305 mm 83 mm 202 mm Package Size W H D V1691 10 0 6 3 3 0 254 mm 159 mm 330 mm V1691E 15 0 6 5 11 3 381 mm 165 mm 286 mm Unit Weight V1691 4 4 lbs 2 kg V1691E 6 6 lbs 3 kg Shipping Weight V1691 7 4 lbs 3 35 kg V1691E 9 6 lbs 4 35 kg Enclosure Aluminum V1691...

Page 17: ...ALARMS RELAYS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 1 2 3 4 5 6 8 7 NONCCM CAMERAS B W S B W S B W S B W S MANCHESTER CODE RS485 PORT T T GND ETHERNET V2011 NONCCM J202 4 V1691 Apply to all V1691 series receiver drivers ...

Page 18: ...22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 B W S B W S B W S B W S ALARMS CODE RELAYS PROG MON RS232 PORTS ETHERNET POWER RS485 T T GND DATA LINE NO NC CM NO NC CM Apply to all V1691 series receiver drivers ...

Page 19: ...TA LINE IN OUT T T G T T G T T G T T G T T G T T G T T G T T G T T G T T G T T G T T G PGM DATA LINE IN OUT EXT SYNC IN OUT CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN POWER PORT OUT 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 1 16 1 2 3 4 5 6 7 8 V2020 Apply to all V1691 series receiver drivers ...

Page 20: ...ROG 1 2 3 4 5 6 7 8 9 CAM 0 MON F1 CLEAR F2 CLOSE OPEN IRIS OFF ON AUXILIARY NEAR FAR FOCUS WIDE TELE ZOOM P A G E P A G E P A G E P A G E USER SITE CONTROL E N T E R E X I T UP DOWN L R POWER MANCHESTER PROGRAM OPERATE MENU RS485 ETHERNET SYSTEM KEYBOARD Infinova R Communication ports on V2116 rear panel Apply to all V1691 series receiver drivers ...

Page 21: ...to all V1691 series receiver drivers 6 Connect the camera Pan Tilt to V1691 with presets AUX2 A AUX2 B AUX1 N O AUX1 N C AUX1 COM LEFT RIGHT VACCOM UP DOWN VACCOM 24VAC J301 TILTPOT PANPOT REF REF FOCUS ZOOMPOT FOCUSPOT GND 12VDC LENSCOM ZOOM IRIS Camera Pan Tilt J300 Note For detailed information of the camera wires please refer to the relevant users manual of the camera in use Apply to all V1691...

Page 22: ...Infinova 51 Stouts Lane Monmouth Junction NJ 08852 U S A Tel 1 888 685 2002 USA only 1 732 355 9100 Fax 1 732 355 9101 sales infinova com V2 1 0808 ...