Chapter 3 - Configuration scenarios
User Manual
R5000 series - Web GUI
101
-
Select both Ethernet and RF interfaces in the pop-up window and then press
the «Ok» button
-
Select strip from the drop-down menu of the eth0 operation modes to strip the
VLAN tag
-
Select In-Trunk mode for the Switch Group #101
-
Set the In-Trunk value to 1, as our BS has the Switch Group 1 configured to
process all CPEs data traffic
Figure 79 - In-Trunk mode, untagged traffic
Step 6b
The Ethernet interface must act as a trunk port in this scenario, so we have to create
a filter rule for the Switch group #101.
In case the client has multiple VLANs, a separate Switch Group should be created
for each VLAN.
We are going to perform the following configuration:
-
Press the «Create Switch Group» button
-
Configure Switch Group 101 in the pop-up window
-
Press the «Ports» button
-
Select both Ethernet and RF interfaces in the pop-up window and then press
the «Ok» button
-
Select In-Trunk mode for the Switch Group #101
-
Set the In-Trunk value to 1, as our BS has the Switch Group 1 configured to
process all CPEs data traffic
-
Open the Rules zone and Press the «Add Rule» button
-
Select VLAN mode and configure the VLAN 101 that must pass within this
Switch Group