XC886/888CLM
Controller Area Network (MultiCAN) Controller
User’s Manual
15-97
V1.3, 2010-02
MultiCAN, V1.0
15.2.4
MultiCAN Access Mediator Register
CAN_ADCON
CAN Address/ Data Control Register
Reset Value: 0000 0000
B
7
6
5
4
3
2
1
0
V3
V2
V1
V0
AUAD
BSY
RWEN
rw
rw
rw
rw
rw
rh
rw
Field
Bits
Type Description
RWEN
0
rw
Read/Write Enable
0
Read is enabled
1
Write is enabled.
BSY
1
rh
Data Transmission Busy
0
Data Transimission is finished.
1
Data Transimission is in progress.
AUAD
[3:2]
rw
Auto Increment/Decrement the Address
00
No increment/decrement the address.
01
Auto increment the current address (+1 )
10
Auto decrement the current address (-1 )
11
Auto increment the current address (+8)
V0
4
rw
CAN Data 0 Valid
0
Data in CAN_DATA0 register is not valid for
transmission.
1
Data in CAN_DATA0 register is valid for
transmission.
V1
5
rw
CAN Data 1 Valid
0
Data in CAN_DATA1 register is not valid for
transmission.
1
Data in CAN_DATA1 register is valid for
transmission.
V2
6
rw
CAN Data 2 Valid
0
Data in CAN_DATA2 register is not valid for
transmission.
1
Data in CAN_DATA2 register is valid for
transmission.
*