XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-83
V1.3, 2010-02
CCU6, V 1.0
Note: If the setting by hardware of the corresponding flags leads to an interrupt, the
setting by software has the same effect.
ISSL
Capture/Compare Interrupt Status Set Register Low
Reset Value: 00
H
7
6
5
4
3
2
1
0
S
T12
PM
S
T12
OM
S
CC
62F
S
CC
62R
S
CC
61F
S
CC
61R
S
CC
60F
S
CC
60R
w
w
w
w
w
w
w
w
Field
Bits
Type Description
SCC60R
0
w
Set Capture, Compare-Match Rising Edge Flag
0
No action
1
Bit ICC60R in register IS will be set.
SCC60F
1
w
Set Capture, Compare-Match Falling Edge Flag
0
No action
1
Bit ICC60F in register IS will be set.
SCC61R
2
w
Set Capture, Compare-Match Rising Edge Flag
0
No action
1
Bit ICC61R in register IS will be set.
SCC61F
3
w
Set Capture, Compare-Match Falling Edge Flag
0
No action
1
Bit ICC61F in register IS will be set.
SCC62R
4
w
Set Capture, Compare-Match Rising Edge Flag
0
No action
1
Bit ICC62R in register IS will be set.
SCC62F
5
w
Set Capture, Compare-Match Falling Edge Flag
0
No action
1
Bit ICC62F in register IS will be set.
ST12OM
6
w
Set Timer T12 One-Match Flag
0
No action
1
Bit T12OM in register IS will be set.
ST12PM
7
w
Set Timer T12 Period-Match Flag
0
No action
1
Bit T12PM in register IS will be set.
*