XC886/888CLM
Capture/Compare Unit 6
User’s Manual
14-44
V1.3, 2010-02
CCU6, V 1.0
T12MSELH
T12 Capture/Compare Mode Select Register High
Reset Value: 00
H
7
6
5
4
3
2
1
0
D
BYP
HSYNC
MSEL62
rw
rw
rw
Field
Bits
Type Description
MSEL62
3:0
rw
Capture/Compare Mode Selection
These bit fields select the operating mode of the three
timer T12 capture/compare channels. Each channel
(n = 0, 1, 2) can be programmed individually either for
compare or capture operation according to:
0000 Compare outputs disabled, pins CC6n and
COUT6n can be used for I/O. No capture action.
0001 Compare output on pin CC6n, pin COUT6n can
be used for I/O. No capture action.
0010 Compare output on pin COUT6n, pin CC6n can
be used for I/O. No capture action.
0011 Compare output on pins COUT6n and CC6n.
01XX Double-Register Capture modes,
see
1000 Hall Sensor mode, see
In order to enable the hall edge detection, all
three MSEL6x must be programmed to Hall
Sensor mode.
1001 Hysteresis-like mode, see
101X Multi-Input Capture modes, see
.
11XX Multi-Input Capture modes, see
.
*