![Infineon TLE5501 E0001 User Manual Download Page 17](http://html.mh-extra.com/html/infineon/tle5501-e0001/tle5501-e0001_user-manual_2055079017.webp)
User’s Manual
17
Rev. 1.0
2019-04-29
TLE5501
TMR-Based Angle Sensor
Calibration
Figure 16 Typical angle error with initial calibration at 25°C/50mT and subsequent measurements
considering 10% magnetic field change due to aging and air gap variation (i.e. 45mT @25°C).
Magnetic field values change with a TC of -2000ppm/K (ferrite magnet material). Magnetic
field values are indicated at each measurement temperature.
0.1
0.15
0.2
0.25
0.3
0.35
-50
-25
0
25
50
75
100
125
150
175
an
gl
e
erro
r
(°
)
temperature (
°
C)
50mT
Initial calibration
50.8mT
49.1mT
47.2mT
45.0mT
42.8mT
39.6mT
36.0mT
33.8mT