SP37
Tire Pressure Monitoring Sensor
ROM Library Functions
ROM Library Function Guide
52
Revision 1.0, 2011-12-15
2.5.6
Resource Usage
2.5.7
Execution Information
Table 32
Meas_Temperature: Resources
Type
Used or Modified
Registers
R0, R1, R2, R3, R4, R5, R6, R7
SFR
ACC, B, CFG0, CFG1, CFG2, DIVIC, DPH, DPL, PSW
Stack
9 Bytes
1)
1) Two additional bytes, not included here, are needed to call the library function
Table 33
Meas_Temperature: Execution Time and Charge Consumption
Parameter
Symbol
Values
Unit
Note / Test Condition
Min.
Typ.
Max.
Execution Time
t
comp
–
668
726
µs
DIVIC = 00
H
,
by default 2 ADC measurements are
taken and averaged
Charge Consumption
Q
comp
–
1,2
1,82
µC
DIVIC = 00
H
,
by default 2 ADC measurements are
taken and averaged