Infineon REF-XDPL8219-U40W Getting Started Download Page 9

  

User Manual 

V 1.0 

 

 

2020-08-12

 

 

Getting started with the XDPL8219 reference board using .dp Vision 
software 

Getting started 

Revision history 

Document 
version 

Date of release 

Description of changes 

 V 1.0 

12-08-2020 

First release 

 

 

 

 

 

 

Summary of Contents for REF-XDPL8219-U40W

Page 1: ...e to operation of the XDPL8219 reference board for all power classes of LED lighting applications and how to use the dp Vision software to program the operating parameters of the XDPL8219 digital cont...

Page 2: ...2 Interface for programming the XDPL8219 digital controller USB cable To connect the dp Interface Gen2 with a PC Please download and install all the software tools Click on the links below Graphical u...

Page 3: ...the recent REF XDPL8219 U40W engineering report Incorrect use of the reference board could be dangerous and even life threatening 2 1 Hardware connection Connect the dp Interface Gen2 to a notebook PC...

Page 4: ...Interface Gen2 connection Figure 3 Connection between the dp Interface Gen2 and the XDPL8219 reference board Note Please ensure that the connector of the programming cable is plugged in correctly The...

Page 5: ...Vision Load the XDPL8219 parameters configuration file csv in the folder HOME Infineon Technologies AG dp vision Parameters as shown in Figure 6 Please select the corresponding file e g for a 40 W boa...

Page 6: ...Getting started Figure 7 Parameters file loaded in dp Vision Note The message bar shown in Figure 7 provides detailed information For further information please refer to the dpvision User manual Figur...

Page 7: ...UART REPORTING parameter is disabled and change the desired parameter value Note If the ENUART REPORTING parameter is enabled the success of the test configuration cannot be guaranteed because dp Visi...

Page 8: ...n 1 Load configuration file see example in Figure 7 2 Modify the parameter value needed then press File Save or File Save as to save the configuration file Otherwise proceed to step 3 3 optional Disco...

Page 9: ...V 1 0 2020 08 12 Getting started with the XDPL8219 reference board using dp Vision software Getting started Revision history Document version Date of release Description of changes V 1 0 12 08 2020 F...

Page 10: ...ended for technically trained staff It is the responsibility of customer s technical departments to evaluate the suitability of the product for the intended application and the completeness of the pro...