6.12.3.4 Register TRAPDIS
This register contains the software disable control for all trap request trigger sources.
Note that the bits ESRxT and RAT in this register also disable the setting of the
respective flags in register DMPMIT (see
).
TRAPDIS
Trap Disable Register
SFR (FE90
H
/48
H
)
Reset Value: 009E
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
VCO
LCK
T
PE
T
RA
T
OSC
WDT
T
ESR
2
T
ESR
1
T
ESR
0
T
FA
T
r
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type
Description
FAT
0
rw
Disable Flash Access Trap Request
0
B
FA trap request enabled
1
B
FA trap request disabled
ESR0T
1
rw
Disable ESR0 Trap Request
0
B
ESR0 trap request enabled
1
B
ESR0 trap request disabled
ESR1T
2
rw
Disable ESR1 Trap Request
0
B
ESR1 trap request enabled
1
B
ESR1 trap request disabled
ESR2T
3
rw
Disable ESR2 Trap Request
0
B
ESR2 trap request enabled
1
B
ESR2 trap request disabled
OSCWDTT
4
rw
Disable OSCWDT Trap Request
0
B
OSCWDT trap request enabled
1
B
OSCWDT trap request disabled
RAT
5
rw
Disable Register Access Trap Request
0
B
RA trap request enabled
1
B
RA trap request disabled
PET
6
rw
Disable Parity Error Trap Request
0
B
PE trap request enabled
1
B
PE trap request disabled
VCOLCKT
7
rw
Disable VCOLCK Trap Request
0
B
VCOLCK trap request enabled
1
B
VCOLCK trap request disabled