6.12.3.2 Register TRAPCLR
This register contains the software clear control for the trap status flags in register
TRAPSTAT. Clearing a bit in this register has no effect, reading a bit always returns zero.
TRAPCLR
Trap Clear Register
SFR (FE8E
H
/47
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
VCO
LCK
T
PE
T
RA
T
OSC
WDT
T
ESR
2
T
ESR
1
T
ESR
0
T
FA
T
r
w
w
w
w
w
w
w
w
Field
Bits
Type Description
FAT
0
w
Clear Flash Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.FAT is cleared
ESR0T
1
w
Clear ESR0 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR0T is cleared
ESR1T
2
w
Clear ESR1 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR1T is cleared
ESR2T
3
w
Clear ESR2 Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.ESR2T is cleared
OSCWDTT
4
w
Clear OSCWDT Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.OSCWDTT is cleared
RAT
5
w
Clear Register Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.RAT is cleared
PET
6
w
Clear Parity Error Access Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.PET is cleared
VCOLCKT
7
w
Clear VCOLCK Trap Request Flag
0
B
No action
1
B
Flag TRAPSTAT.VCOLCKT is cleared