GSCSTAT
GSC Status Register
SFR (FF18
H
/8C
H
)
Reset Value: 3C00
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
SOURCE
PEN ERR
0
NEXT
0
CURRENT
r
rh
rh
rh
r
rh
r
rh
Field
Bits
Type
Description
CURRENT
[1:0]
rh
Currently used Command
This bit field states the currently used system mode.
NEXT
[5:4]
rh
Next to use Command
This bit field states the next to be used system mode.
ERR
8
rh
Error Status Flag
This bit flags if with the last command that was
broadcast was acknowledge with at least one error.
This bit is automatically cleared when a new
command is broadcast.
PEN
9
rh
Command Pending Flag
This flag states if currently a command is pending or
not. A command is pending after the broadcast as
long as no all blocks acknowledge that they finished
the operation requested by the command.