XC2200 Derivatives
System Units (Vol. 1 of 2)
System Control Unit (SCU)
User’s Manual
6-58
V2.1, 2008-08
SCU, V1.13
6.3.7
Reset Controller Registers
6.3.7.1
Status Registers
After a reset has been executed, the Reset Status registers provide information on the
type of the last reset.
Note: After a Power Reset for domain DMP_1 register RSTSTAT0 is not cleared.
Instead it holds the contents it had before the last reset.
RSTSTAT0
Reset Status 0 Register
ESFR (F0B2
H
/59
H
)
Reset Value: 0000
H
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SW
CPU
0
rh
rh
r
Field
Bits
Type
Description
CPU
[13:12] rh
CPU Reset Type Status
00
B
The CPU reset trigger was not relevant for the
last reset
01
B
Reserved
10
B
The CPU reset trigger was relevant for the last
reset. Internal Application and Application
Resets were generated.
11
B
The CPU reset trigger was relevant for the last
reset. Application Reset was generated.
SW
[15:14] rh
Software Reset Type Status
00
B
The Software reset trigger was not relevant for
the last reset
01
B
Reserved
10
B
The Software reset trigger was relevant for the
last reset. Internal Application and Application
Resets were generated.
11
B
The Software reset trigger was relevant for the
last reset. Application Reset was generated.
0
[11:0]
r
Reserved
Read as 0; should be written with 0.