![Infineon Technologies TC1796 User Manual Download Page 846](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437846.webp)
TC1796
System Units (Vol. 1 of 2)
LMB External Bus Unit
User’s Manual
13-68
V2.0, 2007-07
EBU, V2.0
Note: The EBU will issue an LMB Error Acknowledge if an attempt is made to write to an
address that is programmed as Burst Flash unless a lower priority write-enabled
region exists at the same address.
13.9.3
Burst Mode Access Phases
Accesses to asynchronous devices are composed of a number of standard Access
Phases (which are detailed in
). The standard access phases for Burst
Flash devices are:
•
AP: Address Phase (compulsory - see
•
CD: Command Delay Phase (optional - see
•
CP: Command Phase (compulsory - see
•
BP: Burst Phase (compulsory - see
•
RP: Recovery Phase (optional - see
Note: During a burst access, the Burst Phase (BP) is repeated the required number of
times to complete the burst length.
13.9.4
Programmable Parameters
lists the programmable parameters for Burst Flash accesses. These
parameters only apply only when the AGEN bit field in the EBU_BUSCONx or
EBU_EMUBC register for a particular memory region is set to 010
B
or 101
B
(Burst Flash
access).