TC1796
System Units (Vol. 1 of 2)
Program Memory Unit
User’s Manual
7-3
V2.0, 2007-07
PMU, V2.0
Figure 7-2
Basic Diagram of Flash Module
All Flash operations are initiated by transferring command sequences to the Flash that
are based on the JEDEC standard. The command sequences to the Flash are high-level
commands such as “Erase Sector”. State transitions during execution of the commands,
such as termination of command execution or errors, are indicated by status flags and
maskable interrupts. Command sequences are normally written to the PMU by the CPU
but can also be issued by the PCP or the DMA controller.
F
las
h Int
e
rf
ac
e (
P
LMB)
MCB05642
64
Error
Correction
(ECC)
Flash Command
State Machine
(FCS)
Flash Interface &
Control Module (FIM)
2 Mbyte
Program Flash
(PFLASH)
128 Kbyte
Data Flash
(DFLASH)
Bank 0
Bank 1
Flash Array Module
(FAM)
Flash
Control
Logic
Data