![Infineon Technologies TC1796 User Manual Download Page 275](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437275.webp)
TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual
5-53
V2.0, 2007-07
SCU, V2.0
Note: In pad test mode, the bits in SCU_PTDAT0 are output to the pad/pin in inverted
state: a 0 generates a high level and a 1 generates a low level at the pad/pin.
0
17, 18
rw
Reserved
Read as 0; bits
must
be written with 0.
PTMEN
31
rh
Pad Test Mode Enable Flag
0
B
Pad test mode disabled (default after reset)
1
B
Pad test mode enabled
0
[30:19]
r
Reserved
Read as 0; should be written with 0.
SCU_PTDAT0
SCU Pad Test Data Register 0
(F00000B4
H
)
Reset Value: XXXX XXXX
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MR
W
ADV
RD
WR
RD BC3 BC2 BC1 BC0 A23 A22 A21 A20 A19 A18 A17 A16
rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
A15 A14 A13 A12 A11 A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh rwh
Field
Bits
Type Description
An
(n = 0-23)
n
rwh
Pad Test Value for/of EBU Address Bus Line An
BC0
24
rwh
Pad Test Value for/of BC0
BC1
25
rwh
Pad Test Value for/of BC1
BC2
26
rwh
Pad Test Value for/of BC2
BC3
27
rwh
Pad Test Value for/of BC3
RD
28
rwh
Pad Test Value for/of RD
RDWR
29
rwh
Pad Test Value for/of RD/WR
ADV
30
rwh
Pad Test Value for/of ADV
MRW
31
rwh
Pad Test Value for/of MR/W
Field
Bits
Type Description