TC1796
Peripheral Units (Vol. 2 of 2)
Analog-to-Digital Converter (ADC)
User’s Manual
25-59
V2.0, 2007-07
ADC, V2.0
25.2.1
Identification Register
Note: In TC1796 only ADC0_ID is available. There is no ADC1_ID register available.
ADC0_ID
ADC0 Module Identification Register (008
H
)
Reset Value: 0030 C0XX
H
31
16 15
8 7
0
MODNUM
MODTYPE
MODREV
r
r
r
Field
Bits
Type Description
MODREV
[7:0]
r
Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE
[15:8]
r
Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM
[31:16] r
Module Number Value
This bit field defines the module identification number for
the ADC: 0030
H