The write-only Transmitter Pipe x Base Address Register TPxBAR represents the 28-bit
pipe x Remote Window base address and the Remote Window size that is transmitted
to the receiving controller via a Copy Base Address Frame.
TPxBAR (x = 0-3)
Transmitter Pipe x Base Address Register
(54
H
+4
H
*x)
Reset Value: 0000 0000
H
31
4 3
0
ADDR
BS
w
w
Field
Bits
Type Description
BS
[3:0]
w
Buffer Size
This bit field determines the coded buffer size of the
pipe x Remote Window in the receiving controller. When
writing TPxBAR, BS is copied into bit field
TPxSTATR.BS.
0000
B
1-bit offset address of Remote Window
0001
B
2-bit offset address of Remote Window
0010
B
3-bit offset address of Remote Window
…
B
…
1110
B
15-bit offset address of Remote Window
1111
B
16-bit offset address of Remote Window
ADDR
[31:4]
w
Address
This bit field determines the most significant 28 bits of
the pipe x Remote Window base address. When writing
TPxBAR, ADDR is copied into bit field
TCBAR.ADDR[31:4].