![Infineon Technologies TC1796 User Manual Download Page 1490](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371490.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-195
V2.0, 2007-07
MultiCAN, V2.0
The bits in the scheduler instruction status register monitor the information during and
after the instruction collection phase of the scheduler. These values will become valid
when the next time mark is reached.
SISR
Scheduler Instruction Status Register
(2F8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
BCE
V
RME
V
TME
V
ARB
V
ICE
V
TCE
V
RCE
V
r
rh
rh
rh
rh
rh
rh
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ICF GM
ARBM
ALTMSG
TR
EN
CH
EN
IEN
REC
F1
IEN
REC
F0
IEN
TRA
F1
IEN
TRA
F0
INP
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
rh
Field
Bits
Type Description
INP
[3:0]
rh
Interrupt Node Pointer
This bit field indicates the collected INP information.
This value is taken into account only when at least
one of the four interrupt requests is enabled.
IENTRAF0
4
rh
Interrupt Enable if TRAF = 0
This bit field indicates the collected IENTRAF0
information.
IENTRAF1
5
rh
Interrupt Enable if TRAF = 1
This bit field indicates the collected IENTRAF1
information.
IENRECF0
6
rh
Interrupt Enable if RECF = 0
This bit field indicates the collected IENRECF0
information.
IENRECF1
7
rh
Interrupt Enable if RECF = 1
This bit field indicates the collected IENRECF1
information.