![Infineon Technologies TC1796 User Manual Download Page 1421](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371421.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-126
V2.0, 2007-07
MultiCAN, V2.0
Note: The number of scheduler entries following a time mark should not exceed the
number of 10. In order to minimize the required accesses to the scheduler memory
by the scheduler control part, the user should set up the system carefully.
22.6.2.2 Scheduler Entry Type Description
Time Mark Entry
A time mark entry is defined as follows:
TME
Time Mark Entry
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
0
0
1
0
ARBM
IEN
REC
F1
IEN
REC
F0
IEN
TRA
F1
IEN
TRA
F0
INP
rw
rw
rw
rw
r
rw
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TMV
rw
Field
Bits
Type Description
TMV
1)
[15:0]
rw
Time Mark Value
This bit field determines the compare value used for
the next compare action with the cycle time.
INP
[19:16]
rw
Interrupt Node Pointer
INP selects the interrupt output line INT_Om
(m = 0-15) that will be activated when a match is
detected between the cycle time and the time mark
value defined by TMV and if at least one of the four
interrupt conditions is met and enabled.
0000
B
Interrupt output line INT_O0 is selected.
0001
B
Interrupt output line INT_O1 is selected.
…
B
…
1110
B
Interrupt output line INT_O14 is selected.
1111
B
Interrupt output line INT_O15 is selected.