![Infineon Technologies TC1796 User Manual Download Page 1386](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371386.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-91
V2.0, 2007-07
MultiCAN, V2.0
22.4.4
Message Object Registers
The Message Object Control Register MOCTRn and the Message Object Status
Register MOSTATn are located at the same address offset within a message object
address block (offset address 1C
H
). The MOCTRn is a write-only register that makes it
possible to set/clear CAN transfer related control bits through software.
When reading from the MOCTRn address after reset, the reset value of register
MOSTATn will always be delivered (see also
MOCTR0
Message Object 0 Control Register (061C
H
)
Reset Value: 0100 0000H
MOCTR127
Message Object 127 Control Register (15FC
H
)
Reset Value: 7F7E 0000H
MOCTRn (n = 1-126)
Message Object n Control Register
(0061C
H
+n*20
H
)
Reset Value: ((n+1)*01000000
H
)+((n-1)*00010000
H
)
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
SET
DIR
SET
TX
EN1
SET
TX
EN0
SET
TX
RQ
SET
RX
EN
SET
RT
SEL
SET
MSG
VAL
SET
MSG
LST
SET
NEW
DAT
SET
RX
UPD
SET
TX
PND
SET
RX
PND
w
w
w
w
w
w
w
w
w
w
w
w
w
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
RES
DIR
RES
TX
EN1
RES
TX
EN0
RES
TX
RQ
RES
RX
EN
RES
RT
SEL
RES
MSG
VAL
RES
MSG
LST
RES
NEW
DAT
RES
RX
UPD
RES
TX
PND
RES
RX
PND
w
w
w
w
w
w
w
w
w
w
w
w
w
Field
Bits
Type Description
RESRXPND,
SETRXPND
0,
16
w
Reset/Set Receive Pending
These bits control the clear/set condition for RXPND
(see
RESTXPND,
SETTXPND
1,
17
w
Reset/Set Transmit Pending
These bits control the clear/set condition for TXPND
(see
RESRXUPD,
SETRXUPD
2,
18
w
Reset/Set Receive Updating
These bits control the clear/set condition for RXUPD
(see