TC1796
Peripheral Units (Vol. 2 of 2)
Micro Second Channel (MSC)
User’s Manual
21-24
V2.0, 2007-07
MSC, V2.0
Figure 21-16 16-Bit Upstream Reception
Data Reception without Address Field
Frame reception for a 12-bit data frame is selected by USR.UFT = 0. The reception
scheme is comparable with that of the 16-bit data frame reception but there are a few
differences:
•
The upstream counter USR.UC is initially loaded with 01100
B
.
•
The received frame content is always stored in register UD0.
•
Bit field UD0.LABF is always loaded with 00
B
when the frame is stored.
MCT05810
D0
D1
D7
D6
Start
P
16-Bit Upstream Data Frame
A3
A2
Stop Stop
16
15
14
13
12
11
10
4
3
2
1
0
0
A1
5
Sampling
Shifting
A0
SI
Receive
Enabled
f
BR
UC