![Infineon Technologies TC1784 User Manual Download Page 949](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_2055446949.webp)
TC1784
Direct Memory Access Controller (DMA)
User´s Manual
11-131
V1.1, 2011-05
DMA, V3.03
The Memory Checker Write Register is a dummy write-only register that is located within
the memory checker address range.
The Memory Checker Write Register can be used as dummy write register at the write
back action of the DMA or MLI controller Move Engine when the pattern detection feature
of the DMA controller is used. Accessing MCHK_WR with the Move Engine of the MLI
or DMA controller via the Bus Switch of the DMA controller (see
) does not
request the two FPI buses of the TC1784, SPB and DMA, because it is near the MLI
modules address ranges.
MCHK_WR
Memory Checker Write Register
(020
H
)
Reset Value: 0000 0000
H
31
0
WO
w
Field
Bits
Type Description
WO
[31:0]
w
Write-Only
This write-only bit field is used to write dummy data
during DMA pattern detection. The data written to
WO is not taken into account for any action. Any read
action of WO will deliver 0000 0000
H
.
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...