TC1784
System Control Unit (SCU)
User´s Manual
3-88
V1.1, 2011-05
32-bit SCU, V1.18
Figure 3-22 External Request Select Unit Overview
The ERS unit for channel x is controlled via bit field ERCIy.EXISx.
3.3.2.4
Event Trigger Logic (ETL)
For each Input Channel x, an event trigger logic ETLx derives a trigger event and a status
from the input channel x delivered by the associated ERSx unit. Each ETLx is based on
an edge detection block, where the detection of a rising or a falling edge can be
individually enabled. Both edges lead to a trigger event if both enable bits are set (e.g.
to handle a toggling input).
Each pair of the four ETL units has an associated EICRy register, that controls all options
of an ETL (the register also holds control bits for the associated ERS unit pair, e.g.
EICR0 to control ESR0 and ESR1 plus and ETL0 and ETL1).
ERU_ERS_block
M
U
X
Input
channel x
EICRy.EXISx
Input x0
Input x1
Input x2
Input x3
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...