TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-251
V1.1, 2011-05
E-Ray, V3.13
Figure 20-26 ECC Generation and Check
When an ECC error has been detected the following actions will be performed:
In all cases
•
The respective ECC error flag in the Message Handler Status
register is set
•
The ECC error flag
.
in the Error Service Request Register is set, and if
enabled, a module service request to the Host will be generated.
EG
EC
EC
EG
EG
EC
ECC Generator
ECC Checker
EC
EC
Message
RAM
Transient
Buffer
RAM A
Transient
Buffer
RAM B
PRT A
PRT B
Output
Buffer
RAM 1,2
EG
EG
EC
EG
Input
Buffer
RAM 1,2