![Infineon Technologies TC1784 User Manual Download Page 1586](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461586.webp)
TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-210
V1.1, 2011-05
E-Ray, V3.13
•
Wakeup symbol collision resilient for up to two sending nodes (two overlapping
wakeup symbols still recognizable)
•
Wakeup symbol must be configured identical in all nodes of a cluster
•
Wakeup symbol transmit low time configured by
•
Wakeup symbol idle time used to listen for activity on the bus, configured by
•
A wakeup pattern composed of at least two Tx-wakeup symbols needed for wakeup
•
Number of repetitions configurable by
(2 to 63 repetitions)
•
Wakeup symbol receive window length configured by
•
Wakeup symbol receive low time configured by
•
Wakeup symbol receive idle time configured by
.
Figure 20-8 Timing of Wakeup Pattern
20.6.5.6 STARTUP State
The description below is intended to help configuring startup for the E-Ray IP-module. A
detailed description of the startup procedure together with the respective SDL diagrams
can be found in the FlexRay™ protocol specification v2.1, section 7.2.
Any node entering “STARTUP” state that has coldstart capability should assure that both
channels attached have been awakened before initiating coldstart.
It cannot be assumed that all nodes and stars need the same amount of time to become
completely awake and to be configured. Since at least two nodes are necessary to start
up the cluster communication, it is advisable to delay any potential startup attempt of the
node having instigated the wakeup by the minimal amount of time it takes another
coldstart node to become awake, to be configured and to enter startup. It may require
several hundred milliseconds (depending on the hardware used) before all nodes and
stars are completely awakened and configured.
Startup is performed on all channels synchronously. During startup, a node only
transmits startup Frames.
A fault-tolerant, distributed startup strategy is specified for initial synchronization of all
nodes. In general, a node may enter “NORMAL_ACTIVE” state via (see
):
Tx-wakeup Symbol
Rx-wakeup Pattern
(no collision)
Rx-wakeup Pattern
(collision, worst case)
TXL = 15-60 Bit Times TXI = 45-180 Bit Times
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...