Note: The Message RAM is organized in 4-byte words. When received data is stored
into a Message Buffer’s Data Section, the number of 2-byte data words written into
the Message Buffer is PLC rounded to the next even value. PLC should be
configured identical for all Message Buffers belonging to the receive FIFO. Header
2 is updated from Data Frames only.
PLR
[30:24] rh
Payload Length Received
(vRF!Header!Length)
Payload length value updated from received Data Frame
(exception: if Message Buffer belongs to the receive FIFO PLR
is also updated from received NULL Frames). When a message
is stored into a Message Buffer the following behavior with
respect to payload length received and payload length
configured is implemented:
•
PLR > PLC:
The payload data stored in the Message Buffer
is truncated to the payload length configured for even PLC or
else truncated to PLC + 1.
•
PLR
≤
PLC:
The received payload data is stored into the
Message Buffers Data Section. The remaining data bytes of
the Data Section as configured by PLC are filled with
undefined data.
•
PLR = 0:
The Message Buffer’s Data Section is filled with
undefined data.
•
PLC = 0:
Message Buffer has no Data Section configured. No
data is stored into the
Message Buffer’s Data Section.
0
[15:11],
23, 31
r
Reserved
Returns 0 if read; should be written with 0.
Field Bits
Type Description
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...