![Infineon Technologies TC1784 User Manual Download Page 1411](http://html.mh-extra.com/html/infineon-technologies/tc1784/tc1784_user-manual_20554461411.webp)
TC1784
FlexRay™ Protocol Controller (E-Ray)
User´s Manual
20-35
V1.1, 2011-05
E-Ray, V3.13
Lock Register (LCK)
The Lock Register is write-only. Reading the register will return 0000 0000
H
.
LCK
Lock Register
(001C
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TMK
CLK
w
w
Field Bits
Type Description
CLK
[7:0]
w
Configuration Lock Key
To leave “CONFIG” state by writing to SUCC1.CMD commands
READY, MONITOR_MODE, ATM, LOOP_BACK) in the SUC
Configuration Register 1, the write operation has to be directly
preceded by two consecutive write accesses to the Configuration
Lock Key (unlock sequence). If the write sequence below is
interrupted by other write accesses between the second write to
the Configuration Lock Key and the write access to the SUCC1
register, the Communication Controller remains in “CONFIG”
state and the sequence has to be repeated.
First write: LCK.CLK = CE
H
= 1100 1110
B
Second write: LCK.CLK = 31
H
= 0011 0001
B
Third write: SUCC1.CMD
Returns 0 if read
Summary of Contents for TC1784
Page 1: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 3: ...User s Manual V1 1 2011 05 Microcontrollers TC1784 32 Bit Single Chip Microcontroller ...
Page 950: ...TC1784 Direct Memory Access Controller DMA User s Manual 11 132 V1 1 2011 05 DMA V3 03 ...
Page 1949: ...TC1784 General Purpose Timer Array GPTA v5 User s Manual 21 297 V1 1 2011 05 GPTA v5 V1 14 ...
Page 2350: ...w w w i n f i n e o n c o m Published by Infineon Technologies AG Doc_Number ...