6.2.10 Set maintenance interval "Filter sniffer tip" or "Air filter"
To adjust the maintenance interval to the degree of contamination at the location of
the device, you can choose between a default value or a self-selected maintenance
interval.
ü
Supervisor
rights
1
> Setup > Maintenance counters
2
Adjust.
ð
Enter a value of your choice in hours for the "Filter sniffer tip" or press the
adjacent "Default value" button (1000 hours).
ð
Enter a value of your choice in hours for the "Air filter" or press the adjacent
"Default value" button (2500 hours).
3
Save
.
After performing a maintenance, you should reset the desired period until the next
maintenance.
See also
2
Change the filter mat inside the tool box [
2
Replacement of the filter mat on the bottom of the device [
2
Replacing the SL200 sniffer line filter [
2
Replacing the SL3000 sniffer line filter [
6.2.11 Activate or deactivate maintenance requests
Enables or disables warnings when the time for maintenance is exceeded. The time
until the next maintenance is displayed.
ü
Supervisor
rights
1
> Setup > Maintenance requests
ð
In the “Enable/disable maintenance requests” window, you can activate or
deactivate the maintenance requests for the following modules:
- Calibration leak
- TMP
- Filter sniffer tip
- backing pump
- Exhaust filter
- Air filter
2
Adjust.
3
Save
.