8.
TROUBLESHOOTING
Problem:
The motor does not react to commands
Cause:
Thermal cut-out was activated
Solution:
Wait for 10-20 minutes
Problem:
Curtain fins do not close fully
Cause:
The curtain is blocked in the guides
Solution:
Check the roller blind guides and curtain slats
Problem:
The motor stops on its own
Cause:
The curtain is blocked in the guides
Solution:
Check the roller blind guides and curtain slats
Problem:
Blocking hangers were not detected
in semi-automatic programming
Cause:
Roller blind curtain too long.
Solution:
Shorten the curtain to appropriate size.
Problem:
The motor does not detect obstacles when
moving down.
Cause:
Limits programmed wrong way.
Solution:
Reset the drive to factory mode, then repeat the
programming procedure, starting from the upper
limit.
WARNING!
Pauses between individual presses of the remote
control buttons should be at least 1 second long! This
applies both to the programming and operating mode (after
programming limit positions).