Page 23
INE SpA
Via Facca, 10 - 35013 Cittadella - PADOVA - ITALIA Tel. 049/9481111 - Fax 049/9400249 - [email protected] - www.ine.it
13.2 Settings for MIG /MAG welding
Press the ‘T1’ button and keep it pressed. Slide through
the LEDs until the
MIG
welding process indicator LED
gets lit. The release the button.
A fast pressure of button ‘T1’ allows cycling among 2T,
4T and three levels; on the contrary, a longer pressure
than two seconds allows changing the welding process.
2-step mode:
the welding process begins as soon as
the torch trigger is pressed and stops as soon as it is
released.
4-step mode:
when the torch trigger is pressed, the
welding process begins with a manual pre-gas; when
released, the real welding begins. When the torch
trigger is pressed again, the welding will stop, although
gas will still flow; when released, also the manual
post-gas will stop.
3-level mode
]
:
when the torch trigger is pressed,
the welding process begins at the current value set with
parameter
IN1
. When the torch trigger is released, the
current will rise up to the value set with ‘E2’. When the
torch trigger is pressed again, the current will drop
down to the value set with parameter
CRA
. When the
torch trigger is released again, the welding process will
stop.
2-step + 3-level mode
]
:
by pressing the torch
button, the welding process begins with the pregas
interval. Following that period of time, movement of the
wire and power are enabled. Current is set with
INI
and
its duration set with
TIN
. Following this period of time,
current is brought to the set value with ‘E2’. When the
torch button is released, current is brought to the set
value with
CRA
and its duration set with
TCR
.
Following this period of time, post-gas interval takes
place, and thereafter the process stops.
With button ‘T2’ you can set the type of wire and the
protection gas utilized. This operation allows selecting
a synergic welding curve suitable for the chosen
material (for exiting from the preset parameters of
synergy, please refer to the next paragraphs).
Button ‘T3’ allows selecting the diameter of the wire to
be used. An extended pressure on button ‘T3’ will
permit accessing
special processes SP1-SP4
, as well
as selecting any of them that are available. These
special processes can be purchased optionally. For
further information, please contact INE SpA
Button ‘T4’ (gas test) is used for checking the presence
of the welding gas, for verifying the correct flow and for
taking the air out of the circuit.
Button ‘T5’ is used for feeding the wire manually. It is
utilized in particular during a roll change.
By pressing button ‘T5’, the motor will commence
feeding and, with an acceleration ramp of a few
seconds, it will lead the wire at a speed of 15 m/min.
During the whole operation, LED bar ‘L1’ will display the
dragging effort.
With a double and fast pressure of button ‘T5’, feed
direction is reversed so that the wire is recovered. This
is accomplished at minimum speed.
H
SI
L
G
N
E
TORCH BUTTON PRESSED
TORCH BUTTON RELEASED
WELDING
TORCH
STOP
GAS
BUTTON
STOP
t
%I
%I
t
TORCH
WELDING
GAS
BUTTON
STOP
WELDING AREA
STOP
TORCH BUTTON PRESSED
TORCH BUTTON RELEASED
TORCH BUTTON PRESSED
TORCH BUTTON RELEASED
WELDING
TORCH
STOP
GAS
BUTTON
STOP
t
TORCH BUTTON PRESSED
TORCH BUTTON RELEASED
WELDING
TORCH
GAS
BUTTON
STOP
t
STOP
%I
%I