- Check the lubrication system
Orientation
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
The principle of open lubrication requires refilling of lubricating oil.
During maintenance of the lubrication system, first perform a visual inspection of all
components involved in lubrication for leaks and their visual condition. The following
components must be examined during maintenance of the lubricating oil system:
- Lubricating oil tank
- Oil level in lubricating oil tank
- Lubricating oil pump
- Supply and fluid lines
- Pressure gauge
- Metering valves
- Pressure sensors
For all work in connection with operating materials, the information in
the data sheets of the respective manufacturers and the information
in the document Notes on Operating Materials must be observed.
Screws on the lubrication system, the connected components, and
the supply lines must be tightened to the manufacturer's specified
torques.
Requirement
The maintenance of the lubricating oil supply requires the following auxiliary or
working equipment:
- Use an ample supply of cleaning rags.
- A sufficient amount of lubricating oil for refilling/changing.
- Replacement filters for lubricating oil tank.
Oil type, specification and quantity as specified in the technical data.
Use only the original filters according to the spare or wear parts list!
Service and maintenance are to be carried out according to the
manufacturer’s specifications.
Maintenance Summary - 4.000 Operating hours
65
Maintenance Instructions
G220
DIE017EN - 05.06.2019
Summary of Contents for C200-sl
Page 8: ...Preface 4 Maintenance Instructions G220 DIE017EN 05 06 2019 ...