- Check the cooling unit and the coolant
Orientation
For add-on equipment that cannot be cooled conventionally with cooling lubricants
or hydraulic fluid due to high temperature development, separate cooling is provided
in an independent cooling circuit. The coolant used here must be checked
continuously for its condition like other coolants. Also perform a visual inspection of
the cooling unit and the supply and fluid lines as part of the servicing and
maintenance activities. Check for leaks on the system in general as well as at screw
connections, and supply and fluid lines.
This visual inspection or monitoring requires no specific knowledge
of refrigeration according to the manufacturer's documentation.
These activities can be carried out by instructed individuals with
appropriate expertise.
Due to different requirements and/or specifications of the respective
manufacturers, be sure to review the respective manufacturer's
documentation!
Schematic of cooling system G220 G420
1
External cooling unit, or customer-side cooling
2
Heat exchanger (hydraulic unit)
3
Hydraulic unit
4
Heat exchanger (spindles)
5
Main spindle
6
Counter spindle
7
Tool carrier 1
a
Inlet flow (water)
b
Return flow (water)
c
Hydraulic fluid HLPD32 (VG32)
d
Cooling oil HLP5 (VG5)
For all work in connection with operating materials, the information in
the data sheets of the respective manufacturers and the information
in the document Notes on Operating Materials must be observed.
Maintenance Summary - Care activities
25
Maintenance Instructions
G220
DIE017EN - 05.06.2019
Summary of Contents for C200-sl
Page 8: ...Preface 4 Maintenance Instructions G220 DIE017EN 05 06 2019 ...
Page 101: ......