DOCTOR 2
A Guide
for use with
EMIT
Model Types Covered:
EVO 2 Laundry
5407182 Issue 3 June 2006
Page 1: ...on Indesit Company UK Ltd 2006 Reg Office Peterborough PE2 9JB Registered in London 106725 Service WASHING MACHINE DOCTOR 2 A Guide for use with EMIT Model Types Covered EVO 2 Laundry 5407182 Issue 3...
Page 2: ...ication carried out where necessary 7 It can be dangerous to attempt DIY repairs maintenance on complex equipment and the Company recommends that any problem with the appliance is referred to its own...
Page 3: ...s 2 Date Code Serial Number Industrial Code 4 Introduction 5 Requirements Equipment 6 7 Connection to EMIT the Appliance 8 Starting the Software 9 Main Screen 10 13 Using the Software 14 29 Example Te...
Page 4: ...on changes Second five digits COMMERCIAL CODE Vital for correct model information and system identification First two digits Factory of origin 1986 1994 2002 1987 1995 2003 1988 1996 2004 1989 1997 20...
Page 5: ...h Doctor Evo 2 will work with laundry appliances manufactured with EVO 2 software It is important to read this guide fully and view the illustrations carefully before attempting to use the Wash Doctor...
Page 6: ...re Emit Unit Hardware Key Part Number C00115587 Low End Adapter C00116135 USB to Serial lead Part Number 5600261 Hardware Key Pin Kit C00114723 Hardware Key Part Number C00115587 USB to Serial Cable P...
Page 7: ...se products require an adaptor to connect the Emit to the appliance The adaptor is shown below Part Number C00116135 Information on the use of this adapter can be found in leaflet 8200787 Note This pr...
Page 8: ...witch on the appliance Connect the Hardware Key to the appliance A Green Led illuminates on the key During communication with the software Orange and Red Led s on the Hardware Key will flash intermitt...
Page 9: ...When you have the software loaded onto your Emit using the dropdown task bar select Washing Machine Doctor icon This will launch the multi button box shown Next select the WM Doctor Evo 2 button to la...
Page 10: ...WASH DOCTOR EVO 2 MAIN SCREEN This screen will launch when the programme opens after selecting Wash Doctor Evo 2 button 10...
Page 11: ...WASH DOCTOR EVO 2 MAIN SCREEN Press Connection and after a brief delay details of the current appliance will be displayed 11...
Page 12: ...WASH DOCTOR EVO 2 MAIN SCREEN Main Screen APPLIANCE DETAILS TEST COMPONENTS TEST BUTTONS CONNECTION 12...
Page 13: ...various components the Wash Doctor software checks during the test CONNECTION This area shows Connection port Connection button Statistics and Customer Info buttons The Statistics of the test and the...
Page 14: ...a connection and establish the Eeprom and power board are correct in Hardware Configuration section there are two ways to test components Single as shown above or Automatic shown on page 19 In this c...
Page 15: ...USING THE SOFTWARE SINGLE TEST Press the Single button and the software will check the component selected 15...
Page 16: ...USING THE SOFTWARE SINGLE TEST A successful test result will display as shown This confirms the item is ok The result can be printed if required but at present this function is disabled 16...
Page 17: ...USING THE SOFTWARE SINGLE TEST An unsuccessful test result will display as shown 17...
Page 18: ...USING THE SOFTWARE SINGLE TEST If test is unsuccessful a Help File is available by clicking in the white area where the failure is listed A separate box appears with suggestions of possible faults 18...
Page 19: ...OFTWARE AUTOMATIC TEST To test all the components shown simply select Automatic and the programme will progress through components 1 to 21 as applicable to the appliance Leave all the boxes with ticks...
Page 20: ...USING THE SOFTWARE AUTOMATIC TEST A successful test result will display as shown This confirms the item is ok The result can be printed if required but at present this function is disabled 20...
Page 21: ...ill display as shown In this example the pressure switch is stuck full FAIL NO CRITER indicates component NOT TESTED As the valves and the pump rely on the pressure switch they will not test The help...
Page 22: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test you will need to rotate the selector Slowly rotate selector until all Leds light up Then press OK 22...
Page 23: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with variable knobs you will need to rotate them to confirm as shown The pop up window has a time limit 23...
Page 24: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with a display you will need to confirm as shown This has a time limit 24...
Page 25: ...USING THE SOFTWARE BOTH TESTS During Automatic test or Single test for models with Leds you will need to confirm as shown This has a time limit 25...
Page 26: ...TEMPERATURE DURING TEST During the Solenoid Valve tests a pop up window appears showing the temperature of the water during the test 26...
Page 27: ...USING THE SOFTWARE BOTH TESTS If you select Stop the test will cease If you press OK the test will bypass the current component and show it as failed The Ko button is not used 27...
Page 28: ...USING THE SOFTWARE BOTH TESTS Customer Info screen enter information and when you close Wash Doctor the file is saved 28...
Page 29: ...USING THE SOFTWARE BOTH TESTS This shows the Statistics of the test this is saved when closing Wash Doctor 29...
Page 30: ...EXAMPLE TEST Console power board unplugged or detached wires Automatic Test was selected however the component would also fail a Single test 30...
Page 31: ...or pressure switch stuck open Automatic Test was selected however the component would also fail a Single test This shows the valves or filling circuit failure and the pump not tested Note There is no...
Page 32: ...EXAMPLE TEST Open circuit door Automatic Test was selected however the component would also fail a Single test 32...
Page 33: ...EXAMPLE TEST Open circuit heater Automatic Test was selected however the component would also fail a Single test 33...
Page 34: ...EXAMPLE TEST Open circuit drum thermistor Automatic Test was selected however the component would also fail a Single test 34...
Page 35: ...EXAMPLE TEST Open circuit pump Automatic Test was selected however the component would also fail a Single test This shows the test was not carried out on valves and the pump failed 35...
Page 36: ...EXTRA TEST An additional spin test can be carried out using the Extra Test button 36...
Page 37: ...EXTRA TEST This window pops up showing the speed set on the appliance Press Start with the drum empty and the speed achieved is shown 37...
Page 38: ...on of Wash Doctor is being used Impossible to read key Bad connection of key or cable between appliance and computer Check connections Wrong information displayed in Washing Machine Doctor Ensure appl...
Page 39: ...NOTES 39...