Flash Code Messages
Flash Code (I/O Diode D102)
Code Description
Solution
Flash code 2
This indicates to USB connection
fail from System Box to I/O Board.
Connect USB Cable.
Flash Code 3
INFO: Last reboot due to
Watchdog time out.
Turn off game, wait 10 seconds, turn
game on. If the problem persists
call IT tech support.
Flash Code 4
Error when updating USB CID to
latest version.
Turn off game, wait 10 seconds, turn
game on. If the problem persists
call IT tech support.
Flash Code 5
Updated USB CID was detected.
Turn off game, wait 10 seconds, turn
game on. If the problem persists
call IT tech support.
Flash code 6
CID is not connected or is
defective
Check the USB cable connection.
Swap with a known good cable. Call
IT Service for further assistance.
Flash Code 7
CID Malfunction.
Make sure all connections are in
place. Turn off game, wait 10
seconds, turn game on.
Flash Code 10
Error when updating USB I/O
Board to latest version.
Turn off game, wait 10 seconds, turn
game on. If the problem persists
call IT tech support.
Flash Code 11
Updated USB I/O Board was
detected.
Turn off game, wait 10 seconds, turn
game on. If the problem persists
call IT tech support.
Flash Code 12
I/O Board is disconnected.
Make sure all connections are in
place. Turn off game, wait 10
seconds, turn game on.
Flash Code 13
I/O Board malfunction.
Make sure all connections are in
place. Turn off game, wait 10
seconds, turn game on.
Flash Code 14
Incompatible I/O Board.
Make sure all connections are in
place. Turn off game, wait 10
seconds, turn game on.
Miscellaneous Problems
Symptom
Probable Cause
Solution
Unable to exit Operator Menus.
Dipswitch SW202 position 4 is in
the on position.
Set position 4 of SW202 to off.
Press start to exit.
Test switch wired from the I/O
Board is closed.
Verify satellite test switch is not
closed.
Coin Meter is not working
Defective Coin Meter
Replace with a known good one.
Not wired properly
Connect one lead to +5 or +12 volts
depending on device. The other lead
to coin meter on Service Panel Pin
2.
Defective I/O Board
Replace with a known good board.