background image

Manufactured by Taylor Design Group, Inc. P.O. BOX 810262  Dallas, TX 75381

                                                                                                  ©2016 by Taylor Design Group, Inc. All rights reserved.

Before using the INCRA Miter5000, read and follow all of the instructions and safety information in this owner’s manual.

°

 When using the INCRA Miter5000 in conjunction with any other tool, first read and follow all instructions and safety information 

   in that tool’s owner’s manual.

° 

Never let the saw blade come in contact with the aluminum or steel components of the INCRA Miter5000.

° 

Before making any cut, always make sure that the Miter5000’s Sled Base Right is locked securely in the right hand miter slot.

° 

When using the INCRA Miter5000, always keep your hands clear of the saw blade and the line of cut.

° 

Always turn o

 the power and make sure that the saw blade comes to a complete stop before changing the setting of any part of the 

   INCRA Miter5000.

° 

Always securely tighten the large black clamping knob before starting any cut.

° 

Wear safety glasses, hearing protection, and follow all normal shop safety practices.

° 

After making any adjustments to the miter angle or fence position of your INCRA Miter5000, always verify safe clearance between 

   the blade and fence before turning on the saw.

° 

After making any adjustments to the fence position on the INCRA Miter5000, always make sure that the four socket head screws on 

   the fence mounting bracket and the outboard fence lock are securely tightened.

° 

When using the INCRA Flip Shop Stop to position a piece for a cut, always hold or otherwise clamp the board between the stop and 

   the blade.

O

WNER

S

 M

ANUAL

w w w . i n c r a . c o m

Important safety instructions for using the 

INCRA Miter5000

Before using the 

INCRA

Miter5000

, read and follow 

all of the instructions and 
safety information in this 
owner’s manual.

by

SAFETY

Summary of Contents for Miter 5000

Page 1: ...s to a complete stop before changing the setting of any part of the INCRA Miter5000 Always securely tighten the large black clamping knob before starting any cut Wear safety glasses hearing protection and follow all normal shop safety practices After making any adjustments to the miter angle or fence position of your INCRA Miter5000 always verify safe clearance between the blade and fence before t...

Page 2: ...be converted for use on the right side of the blade Just follow the instructions below Remove the hex bolt and the 1 4 x 3 4 pivot shoulder bolt and washers that secure the protractor head to the miter sled and lift the protractor top and bottom plates off Re tain the 1 2 o d steel washer located in the recess on the sled base for reassembly Next remove the 4 Phillips flat head screws that secure ...

Page 3: ...and tooth of the rear actuator with the 0 notch on the 1 2 adjustment plate and tighten the thumbscrew Place the large washer retained in step 2 on the large clamping knob and thread through the slotted hole in the protractor head into the sled base left Before tightening engage the front actuator tooth with the 0 notch on the protractor head Tighten the front actuator thumbscrew then the large cl...

Page 4: ...2 fasteners Fig 12 Loosely install 1 1 4 20 x 3 8 socket head fastener with washer and rectangular nut to the left end of the fence and slide extender bar into fence with the scale face up The higher numbers on the scale should go in first Loosely install 2 1 4 20 x 3 8 socket head screws with washers and rect angular nuts to the 4 fence extender and slide onto the end of the extender bar Position...

Page 5: ... calibration After completing the Calibration and Operation sections of this manual verify this important calibration with a test cut and fine tune as necessary 2 Calibrating the 1 2 Indexing Tooth The 1 2 indexing tooth located on the rear actuator is fac tory calibrated and should require no further adjustment Follow the instructions below should you wish to check the calibration or re calibrate...

Page 6: ...r with the cor responding notch on the protractor head The actuator tooth should point directly to the desired angle on the scale Tighten the large clamping knob then tighten the front actu ator thumbscrew Fig 20 1 2 Indexing 1 Loosen the large clamping knob Loosen the front actua tor thumbscrew and pivot the actuator tooth away from the notches located on the protractor head Rotate the protrac to...

Page 7: ...ners Fig 24A For stopped cuts beyond the range of the main fence you ll need to calibrate the extender bar scale Clamp the IN CRA Flip Shop Stop to the 4 fence extender Use the scale on the short section of fence as a reference for clamping the stop to the same position each time you use it Now loosen the 1 4 20 socket head screw located at the end of the longer fence and slide the 4 fence and ext...

Page 8: ...e positioned slightly behind the front of the arm so that the aluminum arm is the actual stop surface By placing one of the shorter 1 1 2 rods in each of the two stop arms you can use the two stop arms independently Fig 28 For example you can calibrate one for work to the left of the blade and the other for work to the right On one side of the blade you might want to position the stop rods to prov...

Reviews: