IN-24POEGWM
User Manual
24 Port Gigabit Et 4 Combo Gigabit SFP
PoE
+
Web Smart Switch
Page 1: ...IN 24POEGWM User Manual 24 Port Gigabit Ethernet 4 Combo Gigabit SFP PoE Web Smart Switch...
Page 2: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...
Page 3: ...Hardware Description 5 Physical Dimensions Weight 5 Front Panel 5 LEDs Indicators 5 Rear Panel 6 Hardware Installation 6 Software Description 7 Login 7 Configuration 8 System 8 Ports 10 Vlan 11 Aggreg...
Page 4: ...II Detailed Statistic 26 LACP Status 27 RSTP Status 28 IGMP Status 30 VeriPHY 30 Ping 31 Maintenance 34 Warm Restart 34 Factory Default 34 Software Upload 34 Configuration File Transfer 34 Logout 35...
Page 5: ...SNMP RMON IGMP Snooping capability via the intelligent software It is suitable for both metro LAN and office application General Features 24 Gigabit Ethernet ports with non blocking wire speed perfor...
Page 6: ...shaping and policing per port in sites Link aggregation support based on layer 2 4 information IEEE Std 802 3ad Security Port based access control support 4 096 VLAN support VLAN awareness on a per po...
Page 7: ...1Q VLAN Tagging IEEE 802 3ad Link Aggregation IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1p Class of service Priority Protocols IEEE 802 3af 2003 Power over...
Page 8: ...4 Package Contents Before you start to install this switch please verify your package that contains the following items One Switch One Power Cord User Manual CD One pair Rack mount kit 8 Screws...
Page 9: ...The LED Indicators present real time information of systematic operation status This table provides description of LED status and the meaning Table 1 1 LED Indicators LED Status Description Power On P...
Page 10: ...ch on a large flat space with a power socket close by The flat space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables power c...
Page 11: ...e description to understand the procedure At the first open the web browser and go to 192 168 2 100 site then the user will see the login screen The factory default did not set up the password user ma...
Page 12: ...user login the right side of website shows all functions as Fig 1 2 Figure 1 2 Configuration System System Configuration This page shows system configuration information User can configure informatio...
Page 13: ...strial switch The default gateway is 0 0 0 0 Management VLAN ID of a configured VLAN 1 4094 through which you can manage the switch By default all ports on the switch are members of VLAN 1 However if...
Page 14: ...iguration In Port Configuration you can set and view the operation mode for each port Enable Jumbo Frames This switch provides more efficient throughput for large sequential data transfers by supporti...
Page 15: ...reating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physica...
Page 16: ...Traffic in a trunk is distributed across an individual link within the trunk in a deterministic method that called a hash algorithm The hash algorithm automatically applies load balancing to the port...
Page 17: ...Port Configuration Port The port number Enabled Enables LACP on the associated port Key Value Configures a port s LACP administration key The port administrative key must be set to the same value for...
Page 18: ...f 4096 Therefore there are 16 distinct values Hello Time Interval in seconds at which the root device transmits a configuration message BPDU frame Number between 1 10 default is 2 Max Age The maximum...
Page 19: ...on or a link to another STP device Path Cost This parameter is used by the STP to determine the best path between devices Therefore lower values should be assigned to ports attached to faster media an...
Page 20: ...used The client can reject the authentication method and request another depending on the configuration of the client software and the RADIUS server Depending on the authenticated results the port is...
Page 21: ...t s port from the table entry Prevents flooding of IP multicast traffic and limits bandwidth intensive video traffic to only the subscribers IGMP Configuration IGMP Enabled When enabled the switch wil...
Page 22: ...etwork traffic such as an intrusion detection system Mirroring Configuration Port to Mirror to The port that will duplicate or mirror the traffic on the source port Only incoming packets can be mirror...
Page 23: ...te WRR can only be selected if Jumbo Frame mode is disabled on the Port Configuration page Figure 2 9 1 QoS Mode QoS Disabled When the QoS Mode is set to QoS Disabled the following table is displayed...
Page 24: ...IP TCP or UDP header The six bits allow the DSCP field to take any value in the range 0 63 When QoS Mode is set to DSCP the DSCP Configuration table is displayed allowing you to map each of the DSCP...
Page 25: ...iguration table to a common priority queue Use Custom if you want to set each value individually When the QoS Mode is set to DSCP the DSCP Configuration table is displayed as shown below Figure 2 9 4...
Page 26: ...filter configuration Disabled this mode is protected from potential threats like hackers if the traffic from illegal MAC addresses will not be forwarded by the switch Static This table displays the st...
Page 27: ...s from a power supply within a PoE enabled networking devise such as Switch or can be injected into a cable run with a midspan power supply This figure shows all the PoE s status when connect or disco...
Page 28: ...roadcast storms may occur when a device on your network is malfunctioning or if application programs are not well designed or properly configured If there is too much broadcast traffic on your network...
Page 29: ...is set by a single drop down list The same threshold is applied to every port on the switch When the threshold is exceeded packets are dropped irrespective of the flow control settings Web Click PORT...
Page 30: ...target port for real time analysis the following figures shows clearly the statistics overview Figure 3 1 Detailed Statics To view the statistics of individual ports click one of the linked port numb...
Page 31: ...ive LACP group Partner Port Number A list of the ports attached at the remote end of this LAG link member Operational Port Key Current operational value of the key used by this LAG LACP Port Status Ac...
Page 32: ...28 Figure 3 3 2 RSTP Status RSTP VLAN Bridge Overview Figure 3 4...
Page 33: ...guration The time required for reconfiguration is extremely short so no values other that steady state are likely to be seen in this field Root ID The priority and MAC address of the device in the Spa...
Page 34: ...mber of received v2 Report packets v3 Reports Show the number of received v2 Report packets v3 Leave Show the number of v3 leave packets received Figure 3 5 VeriPHY VeriPHY Cable Diagnostics User can...
Page 35: ...site on the network can be reached The following are some results of the ping command Normal response The normal response occurs in one to ten seconds depending on network traffic Destination does not...
Page 36: ...32 Figure 3 7 1 Figure 3 7 2...
Page 37: ...33 Figure 3 7 3...
Page 38: ...y IP Address will be reset to their factory Figure 4 2 Software upload Select Upgrade Firmware from the Tools drop down list then click on the Browse button to select the firmware file Click the APPLY...
Page 39: ...configuration Use the Browse button to choose a file location on the web management station or to find a saved configuration file Figure43 4 Logout The administrator has write access for all paramete...
Page 40: ...he Web Smart Switch back to the original default Step 1 Turn on the Web Smart Switch Step 2 Press and hold the reset button continuously for 5 seconds and release the reset button Step 3 The switch wi...