Liquid ring vacuum pumps

LR 060-H06, LR 061-H16

Summary of Contents for LR 060-H06

Page 1: ...www in eco eu Air and Vacuum Components Operating Instructions Liquid ring vacuum pumps LR 060 H06 LR 061 H16...

Page 2: ......

Page 3: ...on with operating liquid feed 13 6 Transport and Handling 14 7 Installation 15 7 1 Installation 15 7 2 Electrical connection motor 16 7 3 Connecting pipes hoses vacuum pump compressor 17 7 3 1 Inlet c...

Page 4: ...zed parts 30 11 4 Service After sales service 30 11 5 Decontamination and Declaration of Clearance 30 12 Disposal 30 13 Accessories 31 13 1 Flanges 31 13 2 Non return valve 31 13 3 Gas ejector 32 13 4...

Page 5: ...05...

Page 6: ...taken WARNING Improper use of the unit can result in serious or even fatal injuries These operating instructions must have been read completely and understood before beginning any work with or at the...

Page 7: ...onnection as well as to the operating liquid port WARNING Danger in the form of cuts or cutting off extremities on the impeller of the pump motor unit Do not reach into the unit through open connectio...

Page 8: ...d for operation with the following operating liquids Water with a pH of 6 to 9 free of solid materials such as sand If the pH values or operating liquids differ it is necessary to contact service are...

Page 9: ...7 100 125 144 5 G1 171 139 5 165 13 5 G1 4 G1 4 G1 2 73 5 G1 4 G1 4 Typ A1 A2 LR 060 H16 368 4 287 9 LR 061 H06 386 7 287 9 1 Casing 2 Port plate 3 Impeller 4 Lantern 5 Motor 6 Mechanical seal The re...

Page 10: ...t temperature max 40 C 104 F min 5 C 41 F Min inlet pressure Dependent on the operating liquid temperature see Fig 2 Pg 10 When this temperature is dropped below the hose ofthe liquid separator access...

Page 11: ...60 Hz LR 060 H16 0 20 0 20 7 06 7 06 LR 061 H06 0 23 0 23 8 12 8 12 Type Filling amount l gal US gal UK LR 060 H16 0 40 0 106 0 088 LR 061 H06 0 55 0 145 0 121 water Requirement L min water Requiremen...

Page 12: ...sucked in through the inlet port The space in the cells is largest at the lower vertex as these are virtually free of operating liquid During the second half rotation the liquid ring approaches the hu...

Page 13: ...tain volume flow nominal operatingliquid flow rate or pre pressure must be set for the operating liquid Here the following additional distinctions are made Non automatic operation In this case the ope...

Page 14: ...ual to the unit s weight The pump motor unit must be secured so that it cannot tip or fall Do not stand or walk under suspended loads WARNING Danger from tipping loads Be sure to observe the routing o...

Page 15: ...earances for heat dissipation and cooling see Chapter 4 1 Mechanical data Section Minimum distances for heat dissipation Pg 10 The pump motor unit must be installed as follows on level surfaces with s...

Page 16: ...ulations according to the applicable systemdependent prescriptions and requirements according to the applicable regulations of the utility company DANGER Electrical danger Malpractice can result in se...

Page 17: ...pipes hoses to the unit To do this pour operating liquid into the open inlet connection discharge connec tion or operating liquid port For proper filling quantities see Chapter 4 3 Operating conditio...

Page 18: ...ng upward Connect the dis charge pipe here Both the pumped gases vapors and the operating liquid are discharged via this pipe 7 3 3 Operating liquid port The operating liquid port Fig 7 Pg 17 is locat...

Page 19: ...ipe Fig 12 Pg 22 item 4a Then proceed with commissioning as described in the following i NOTICE Maximum permissible quantity of water entrai ned via the inlet connection See Fig 13 Pg 22 WARNING Dange...

Page 20: ...p compressor depres surize DANGER Electrical danger The electrical connection may be carried out by trai ned and authorized electricians only DANGER Electrical danger Before beginning work on the unit...

Page 21: ...y The operating liquid is fed in Switch on the unit For automatic operation Fig 12 Pg 22 Switch on the unit The solenoid valve Item 4 opens and the operating liquid is fed in 2 Check the operating liq...

Page 22: ...ter entrained via the inlet connection 1 Pump motor unit 2 Flow meter 3 Control valve 1 Pump motor unit 2 Flow meter 3 Control valve 4 Solenoid valve connected to motor A During continuous operation 3...

Page 23: ...ontained in Chapter 8 2 Self priming operation Pg 20 for this operating mode 9 2 Operation with operating liquid feed Start up For non automatic operation Fig 11 Pg 22 Open the stop valve Item 4 manua...

Page 24: ...the intake and discharge connection as well as the operating liquid port and remount the disconnected pipes hoses Guide a M6 or M8 bolt depending on the type with a sufficient shank length through th...

Page 25: ...Pg 19 10 3 Storage conditions DANGER Electrical danger Work on electrical installations may be carried out by trained and authorized electricians only DANGER Electrical danger Before beginning work o...

Page 26: ...ing the pump motor unit proceed as described in Chapter 8 Commissioning Pg 19 Impeller is jammed Shut unit down Guide a M6 or M8 bolt depending on the type with a suffici ent shank length through the...

Page 27: ...out protective measures for the use of compressed air Wear personal protective equipment protective gloves and safety goggles secure surroundings Remove objects lying around Blow in compressed air th...

Page 28: ...switch trips when motor is switched on Winding shortcir cuit Have winding checked Electrician Motor overloaded Throttle operating liquid flow rate See Chapter 8 2 Self priming operation Pg 20 or 8 3 O...

Page 29: ...on of arrow shown on housing see Fig 15 Pg 27 Remove the housing Examine the impeller for erosion Have the impeller replaced by Service if necessary Screw on the housing again opposite direction of a...

Page 30: ...unit so that it is residue free as described in Chapter 10 1 Draining Pg 24 Clean the unit on the inside and outside as described in Chapter 11 1 Maintenance Pg 26 The pump motor unit must be deliver...

Page 31: ...on the inlet connection Use commercially available liquid sealant e g Loctite when doing so Tightening torque depen dent on the sealant Screw the inlet pipe onto the non return valve Use commerci all...

Page 32: ...d as follows Screw the gas ejector onto the inlet connection Use com mercially available liquid sealant e g Loctite when doing so Tightening torque dependent on the sealant Screw the inlet pipe onto t...

Page 33: ...iquid sealant e g Loctite when doing so Screw the reducer into the liquid separator again 3 Screw the hose nipple into the hole provided on the pump motor unit Use commercially available liquid sealan...

Page 34: ...essure increases above the evaporation pressure again on the discharge side or at points with a larger cross section these gas bubbles collapse while forming high pressure peaks which may lead to part...

Page 35: ...35 Fig 21 Mounting liquid separator Part 2 of 2 Accessories IN ECO spol s r o 5 6 7 8...

Page 36: ...Item No Part Designation 050 Valve plate 051 Intercepting plate 053 Special screw 058 O ring 068 Screw plug 069 Sealing ring 072 Washer for cavi tation protection 079 Screw plug 080 Sealing ring 095 C...

Page 37: ...N ECO spol s r o 14 2 Exploded view Fig 22 Exploded view vacuum pump compressor section Example delivered version may differ in some details 053 058 035 051 049 045 127 002 125 047 068 069 050 036 025...

Page 38: ...0 641 663 662 095 005 006 001 008 467 455 450 451 452 501 500 503 A 042 Exploded View with Parts List IN ECO spol s r o 14 2 Exploded view motor section Fig 23 Exploded view motor section Example deli...

Page 39: ...mit the life expectancy of the equipment and could void any warranties if they are the cause of any damage Operating conditions beyond our control such asimproper voltage or water pressure excessive a...