A-20
MForce MicroDrive Motion Control Hardware Manual Revision R112706
PD10-1434-FL3 Connections
Color
Combination
Flying Lead End
Connections Cable 1
MForce #1 Wire Crimp
Connection
White/Blue
RX+ (Comm Host)
TX+ (Pin 1)
Blue/White
RX+ (Comm Host)
TX- (Pin 4)
White/Orange
TX+ (Comm Host)
RX+ (Pin 6)
Orange/White
TX- (Comm Host)
RX- (Pin 3)
Green/White
COMM GND (Comm Host)
COMM GND (Pin 2)
White/Red
AUX-Power (At Supply)
AUX-Power (Pin 5)
MForce #2 Wire Crimp Connection
Color
Combination
Flying Lead End
Connections Cable 2
MForce #2 Wire Crimp
Connection
White/Blue
TX+ (Pin 9 - Cable 1)
TX+ (Pin 1)
Blue/White
TX- (Pin 10 - Cable 1)
TX- (Pin 4)
White/Orange
RX+ (Pin 7 - Cable 1)
RX+ (Pin 6)
Orange/White
RX- (Pin 8 - Cable 1)
RX- (Pin 3)
Green/White
COMM GND (Comm Host)
COMM GND (Pin 2)
White/Red
AUX-Power (At Supply)
AUX-Power (Pin 5)
Table D.3: PD10-1434-FL3 Wire Color Codes
Prototype Development Cable PD10-1434-FL3 (All MForce Motion Control)
The PD10-1434-FL3 is used to connect to the 10-pin wire crimp option for interfacing RS-422/485 Com-
munications. It also features an additional cable attached for multi-drop communications systems.
Setup Instructions — Cable #1
Cut crimp pins from Communications Wires and strip insulation back approximately 1/4”.
Connect receive (RX) and transmit (TX) lines as shown in the diagram and table above to your
RS-422/485 Host interface.
Connect Communications Ground line to the Comm Ground of your RS-422/485 Host.
Connect Aux-Power (if used) to the +VDC Output of a +12 to +24 VDC Supply.
Connect the return (GND) of the Aux-Supply to Power Ground of the MForce.
Plug the wire crimp connector of Cable #1 into P2 of the MForce #1.
Setup Instructions — Cable #2 and Subsequent MForce MicroDrives
Insert the crimped transmit and receive lines into the 10-Pin wire crimp connector of Cable #1 as
shown in the diagram and table.
Connect communications ground (May be daisy-chained).
Connect Aux-Supply at the +VDC output of the +12 to +24 VDC Supply (May NOT be daisy-
chained).
Plug the wire crimp connector of Cable #2 into P2 of MForce #2
Repeat Steps 1-4 for each additional MForce MicroDrive in the system.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
Note:
If using the
PD10-1434-FL3
for a single MForce
System, follow only the setup
instructions for Cable #1.
Additional cables are not
required