Installation

Guide

www.imPowerDealer.com

Summary of Contents for 5SME29DFT001

Page 1: ...Installation Guide www imPowerDealer com...

Page 2: ...standard PSC induction motors This not only saves the Earth s precious resources but also saves the consumer hundreds of dollars per year in energy costs Why Choose Marathon Electric Our fast response...

Page 3: ...pside Interface Overview 9 Single Speed Connection with Timer 10 Two Speed Connections with Timer 13 Automation Controller Signal Line Connection 16 Automatic Reduced Speed Selection 20 Software Error...

Page 4: ...ould be installed in accordance with accepted practices and installation instructions and in compliance with all national and local codes 1 Safety Considerations The following definitions are used as...

Page 5: ...instructions and training manual This motor should be installed in accordance with accepted practices and installation instructions and in compliance with all national and local codes 1 The following...

Page 6: ...table speeds either through the use of the patent pending auto speed switch feature top panel push buttons external multi speed timers or through external automation controls RB003 Model Number 5SME29...

Page 7: ...tomatically turn down to one of the two reduced speeds The factory default reduced speed setting is low 1725 rpm though this can be modified to medium 2600 rpm if the flow pressure at low is deemed in...

Page 8: ...seal from the existing motor when installing the imPower motor Remove the screws holding the seal plate onto the motor Step 5 Remove the pump motor by removing the four bolts holding the motor to the...

Page 9: ...g high speed via a button press 3 After selecting high speed via a timer or automation controller This condition is present 1 After selecting medium speed via a but ton press 2 After selecting medium...

Page 10: ...re refer to Figure 6 Step 5 Connect the ground to the block opening directly across from the GREEN YELLOW wire refer to Figure 6 Step 6 Screw in the conduit connector into the terminal box on the righ...

Page 11: ...ctor to the supplied grounding bonding lug Step 15 Open the inlet and outlet valve Step 16 Reapply power and allow motor to accelerate to high speed and operate there for at least two minutes to assur...

Page 12: ...urned off at the timer and turned back on Extended Functionality The imPower motor also has the ability to operate on high speed for only the mandatory two minute pump priming cycle before changing to...

Page 13: ...llowing steps to properly operate the motor with the multi speed timer Proceed to step 5 if a multi speed timer is already installed and operating a two speed induction motor Step 1 Remove the caution...

Page 14: ...0 Step 9 Connect the L2 to the opening directly across from the WHITE wire on the terminal block refer to Figure 10 Step 10 Connect the ground to the opening directly across from the GREEN YELLOW wire...

Page 15: ...he pool can meet the total number of turns as required by local state regulations 2 The user can override the operational speed currently running via the buttons on the top control panel after the man...

Page 16: ...pening directly across from the GREEN YELLOW wire on the terminal block refer to Figure 11 Step 6 Screw in the conduit connector into the terminal box on the right side of the terminal box shaft facin...

Page 17: ...hten the connector nut Step 12 The connection of the low voltage wires at the automation controller should be to the HOT side of the auxiliary AUX relays red and black wire on the top side of the rela...

Page 18: ...the seal plate onto the motor Step 16 Put a NEW pump seal into the seal plate Handle and lubricate seal per manufacturer s specifications Step 17 Replace the impeller Make sure that the impeller can s...

Page 19: ...e pool can meet the total number of turns as required by local state regulations 2 The user can override the operational speed currently being set by the automation controller via the buttons on the t...

Page 20: ...ed speed operation Step 1 Allow the pump to achieve prime if starting the system for the first time Step 2 Turn power to the motor off at the timer controller once pump prime is reached Also turn powe...

Page 21: ...convert to the new default speed 3 For a multi speed timer the motor will stay at high speed for the remainder of the Circuit 1 time setting The new default reduced speed will begin during the second...

Page 22: ...ed below 180 volts AC running The controller will reboot after voltage comes above 209 volts AC for at least 6 seconds Reduce distance between motor pump and breaker Turn off any other non critical eq...

Page 23: ...breaker and allow motor to remain off for at least 15 minutes before reapplying power Return motor for warranty if error persists 8 Motor fault One or more of the phases has become disconnected Turn...

Page 24: ...ld operate as required 3 Issue Motor will not change speeds when requested by the automation controller Action Refer to the appropriate section in this guide to confirm the cable connections to the co...

Page 25: ...ed speed to medium per the appropriate procedure outlined in this guide 6 Issue Pool cleaner is not working properly Action Assuming this issue was not pre existing the programmed low speed on the imP...