Cheetah Pregius Camera with GigE Vision
®
Interface – User Manual
August 27, 2019
Page
92
of
123
Rev 1.0
Pulse Generator Controls
The Pulse Generator provides a signal generator for camera sourced trigger or control
signals.
Figure 56:
Pulse generator parameters
PulseGenGranularity
Sets the Pulse Generator main timing resolution. The x1 resolution is
in microseconds. The following four granularity steps are possible:
x1, x10, x100, x1000 (x1000 is equal to 1ms timing resolution).
PulseGenWidth
Sets the value of the pulse width in microseconds.
PulseGenPeriod
Sets the value of the pulse period in microseconds.
PulseGenNumPulses
Sets the number of pulses generated by the Pulse Generator. To set
Pulse Generator in continuous mode, set the parameter in 65536.
PulseGenEnable
Enables the Pulse Generator.
Canon Lens Control
The POE-C4410, POE-C5410, and POE-C6410 cameras support Canon EF Active lens mount. If
using Canon lens control, the following parameters are available for controlling the lens or
checking its status.
Figure 57:
Canon lens control general parameters
GetLensStatus
Request the value of the LensStatus register.
LensStatus
Returns the status of the lens after the GetLensStatus runs.