Imperial
Cal. Products, Inc.
Installation Guide
And Users Manual
MODELS:
TG5000PS-SS – Island Hood
&
TW5000PS-SS – Wall Hood
425 Apollo St.
Brea, CA 92821
www.imperialhoods.com
800-851-4192
DO NOT THROW AWAY
PROPERTY OFTHE HOME OWNER
Page 1: ...l Products Inc Installation Guide And Users Manual MODELS TG5000PS SS Island Hood TW5000PS SS Wall Hood 425 Apollo St Brea CA 92821 www imperialhoods com 800 851 4192 DO NOT THROW AWAY PROPERTY OFTHE...
Page 2: ...ooting P 11 J Maintenance P 12 K Wiring Diagram P 13 READ AND SAVE THESE INSTRUCTIONS SAVE THIS GUIDE FOR THE LOCAL ELECTRICAL INSPECTOR S USE APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE O...
Page 3: ...mponents operating blowers could catch on the hair and loose clothing 3 NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers 4 NEVER leave cooking unattended When fry...
Page 4: ...metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN you may be burned 3 DO NOT...
Page 5: ...through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary G A UL or C S A listed conduit connector mush...
Page 6: ...or assembly 2 Check carefully to make sure that no mounting hardware or parts are missing 3 DO NOT REMOVE THE PLASTIC COVERING ON THE DUCT COVERS AT THIS TIME As it protects the duct covers from scrat...
Page 7: ...tion duct set for discharge of fumes to the outdoor Vent work can terminate either through the roof or wall To vent through a wall a 90 degree elbow is needed IMPORTANT Vent system must vent to the ou...
Page 8: ...verted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of charcoal filters The air is then purified and re circulated b...
Page 9: ...out a circle of 7 1 2 diameter for duct work 2 Screw down the screws on the supporting frames then pull down the frames to adjust it to the length required then place outer support frames onto the inn...
Page 10: ...ame and secure it with eight 4mm x 16mm screws and washers figure 8 INSTALLATION ALUMINUM TUBE 8 Install the aluminum duct on to the body of the hood and connect the duct to the exterior exhaust syste...
Page 11: ...e hood and connect the duct to the exterior exhaust system Make sure all joints are secure and air tight Use certified Silver Tape or Duct Tape to make all joints secure and air tight figure 5 7 Remov...
Page 12: ...IONS Model Island Type of Range Hood Wall Mount Type of Range Hood Power Rating 120V 60Hz USA Canada standard General Input Power 164W 160W 4 x 1W 162W 160W 2 x 1W Motor Input Power 160W 160W Motor Re...
Page 13: ...ntly with insufficient duct size Check if duct is clogged or if damper unit is not opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow 4 The lights work...
Page 14: ...Do not use corrosive abrasive detergent e g Comet Power Scrub EZ off oven cleaner or steel wool scoring pads which will scratch and damage the stainless steel surface For heavier soiled areas use a li...
Page 15: ...the range hood 2 Make sure the lights are cool to touch Use a flat hand screwdriver or equivalent tool carefully turn the inner ring counter clockwise with to pop out the protective covering of the li...
Page 16: ...household use 4 Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with the electrical or plumbing codes 5 Replacement p...