Appendix A: EzUHF Configuration
The single-cable PPM connection between the EzUHF receiver and the Vortex power board
requires v1.51 (or later) of firmware to support the uplink status.
The configuration of the EzUHF receiver should be as follows:
1)
10 Channel PPM output
2)
PPM on servo channel 1
3)
UPSTAT on PPM slot 10
Note: To ease programmation of UPSTAT on a receiver equipped with v1.51 of firmware, a new
version of the ImmersionRC tools is required, v1.41. This is now available from our website.
Simply click the ‘Configure for XuGong v2/Pro’ to setup your EzUHF receiver.