3.2  WIRING DIAGRAM.

Key:

  A5  - CAR

V2

 interface card

 

B1  -  Delivery probe

 

B2  -  Domestic water probe

 

B4  -  External probe (optional)

 CAR

V2

  -  Remote Friend Control

V2

  

  (optional)

  CRD  -  Remote digital control (optional)

 

E1  -  Ignition plugs

 

E2  -  Igniter sensor

 

E4  -  Safety thermostat

 

F1  -  Neutral fuse

 

F2  -  Line fuse

  M1  -  Boiler circulating pump

  M20  - Fan

  M30  -  3-way valve (motorised)

 

R5  -  Domestic water temp. trimmer 

 

R6  -  Heating temp. trimmer 

  R10  -  Main selector switch

 

S6  -  Fumes pressure switch

 

S8  -  Gas type selector

  S20  -  Environment thermostat (optional)

 

T2  -  Switch-on transformer

  X40  -  Environment thermostat jumper

 

Y1  -  Gas valve

 

Y2  -  Gas valve modulator

 

1  - Primary

 

2  - Secondary

 

3  -  230 Vac 50Hz Power supply

 

4  -  230 Vac 50Hz max 2° aux. output

 

5  -  Card area

 

6  - Yellow/Green

 

7  - Blue

 

8  - Brown

 

9  - White

 

10  - Green

 

11  - Red

 

12  - Black

 

13  - Grey

 

14  - Heating

 

15  -  Domestic water

Remote controls: the boiler is designed to use 

the Remote Friend Control

V2

 (CAR

V2

), or as an 

alternative to the Digital Remote Control (CRD) 

which must be connected to clamps 42 and 43 of 

connector X9 for the CAR

V2

 (respecting polarity) 

and clamps 40 and41 of connector X9 for the CRD 

on the circuit board and in both cases eliminating 

X40.
Environment thermostat (alternative to the CRD): 

the boiler is designed to use the Room Thermostat 

(S20). Connect it to clamps 40 – eliminating 

jumper X40.
Connector X12 (RS 232) is used for automatic 

inspection for connection to the personal 

computer.

3.3 TROUBLESHOOTING.

N.B.: 

Maintenance must be carried out by a 

qualified technician (e.g. Immergas Technical 

Assistance Service).
-  Smell of gas. Caused by leakage from gas circuit 

pipelines. Check sealing efficiency of gas intake 

circuit.

- The fan works but ignition discharge does not 

occur on the burner train. The fan may start but 

the safety air pressure switch does not change the 

contact. Make sure:

1)  the intake/exhaust duct is not too long (over 

allowed length).

2)  the intake/exhaust duct is not partially blocked 

(on the exhaust or intake side).

3)  the diaphragm on the fume exhaust is adequate 

for the length of the intake/exhaust ducts.

4)  the fan power supply voltage is not less than 

196 V.

- Irregular combustion (red or yellow flame). 

This may be caused by a dirty burner, incorrect 

combustion parameters, intake-exhaust 

terminal not correctly installed. Clean the above 

components and ensure correct installation of 

the terminal.

-  Frequent activation of the temperature overload 

thermostat. This may be caused by lack of water 

in the boiler, insufficient water circulation in 

the circuit or a blocked circulator. Check via the 

pressure gauge that values are within admissible 

limits. Check that radiator valves are not all 

closed.

-  Presence of air in the system. Check opening of 

the special air bleeding cap (Fig. 1-30). Make 

sure the system pressure and expansion tank 

pre-charge values are within the set limits; the 

pre-charge value for the expansion tank must be 

1.0 bar, and system pressure between 1 and 1.2 

bar.

-  Ignition block: (Para. 2.5).
- Domestic water probe broken. The boiler does 

not have to be emptied in order to replace the 

domestic water probe as the probe is not in direct 

contact with the domestic hot water present in 

the boiler.

Summary of Contents for ZEUS 24 Superior

Page 1: ...ZEUS 24 28 kW IE Instruction booklet and warning 1 038761ENG...

Page 2: ...ct correctly Maintenance must be carried out by skilled technical staff The Immergas Authorised After sales Service represents a guarantee of qualifications and professionalism The appliance must only...

Page 3: ...sure sufficient space for normal servicing therefore it is advisable to leave a clearance of at least 3 cm between the boiler casing and the vertical sides of the cabinet Leave adequate space above th...

Page 4: ...ranty before making the boiler connections carefully clean the heating system pipes radiators etc with special pickling or de scaling products to remove any deposits that could compromise correct boil...

Page 5: ...t function disabled i e it must be set to On Off mode The CRD cannot be used for plants divided into zones Electrical connection of the Remote Friend ControlV2 or chronothermostat On Off Optional The...

Page 6: ...s Cut the seal in the relative groove at the desired diameter 80 run it along the bend and fix it using the sheet steel plate Insert the exhaust pipe with the male end smooth into the female side of t...

Page 7: ...the boiler the fumes separator positioned on the air fumes extraction well must be adjusted Fig 1 12 Adjustment is carried out by loosening the front retainer screw and moving the indicator to the cor...

Page 8: ...Exhaust m 2 0 Terminal complete with concentric hori zontal intake exhaust 80 125 Intake and Exhaust 33 m 2 0 m 5 5 Intake m 14 3 Exhaust m 11 0 Terminal complete with concentric horizontal intake exh...

Page 9: ...t kits 80 125 Kit assembly Fig 1 18 install the bend with flange 2 on the central hole of theboiler inserting the seal 1 and tighten using the screws in the kit Fit the male end smooth of the adapter...

Page 10: ...flues and air intake pipes according to the diagram shown in the figure Fig 1 22 Fumes are expelled from duct S Air is taken in through duct A for combustion Intake duct A can be installed either on...

Page 11: ...red use 80 pipes with insulation see insulated separator kit 80 80 chapter Insulated separator kit 80 80 Kit assembly Fig 1 26 install flange 4 on the central hole of the boiler fitting seal 1 and tig...

Page 12: ...kit optional air intake takes place directly from the environment in which the boiler is installed and the fumes are expelled in an individual flue or directly to the outside The boiler in this config...

Page 13: ...tail to ensure maximum reliability Thelowerinspectionflangeensurespracticalcontrol oftheboilerandthecoiledheatexchangerandeasy internal cleaning The domestic water attachments are found on the flange...

Page 14: ...irculation pump 9 Gas valve 10 3 way valve motorised 11 System filler tap 12 System expansion tank 13 Domestic hot water probe 1 17 ZEUS 24 28 KW BOILER COMPONENTS 14 Stainless Steel Boiler 15 3 bar s...

Page 15: ...devices for flue extraction and relative accessories switch off the appliance and on completion of operations ensure that a qualified technician checks efficiency of the ducting or other devices Neve...

Page 16: ...it and that the system is free of air deaerated circulating pump blocked free the circulating pump If this phenomenon occurs frequently contact a qualified technician for assistance e g Immergas Techn...

Page 17: ...elow 4 C and stops once it exceeds 42 C The antifreeze function is guaranteed if the boiler is fully operative and not in block status and is electrically powered To avoid keeping the system switched...

Page 18: ...nd or exhaust terminals are not blocked check activation of the no air safety pressure switch ensure activation of all adjustment devices seal the gas flow rate regulation devices if settings are modi...

Page 19: ...ESHOOTING N B Maintenance must be carried out by a qualified technician e g Immergas Technical Assistance Service Smell of gas Caused by leakage from gas circuit pipelines Check sealing efficiency of...

Page 20: ...f gas by turning in a clockwise direction the heating potential increases and in an anti clockwise direction it decreases Adjust the boiler minimum thermal input Fig 3 3 N B only proceed after having...

Page 21: ...seconds LED 7 650 seconds Standard setting LED 8 Heating switch on delay request from Room thermostat and Remote Friend ControlV2 The boiler is set to switch on immediately after a request In the cas...

Page 22: ...n the casing Unhook the lower part of the casing as described in the figure Pull the casing 4 forwards and up at the same time see figure to detachit from the upper hooks 3 15 YEARLY APPLIANCE CHECK A...

Page 23: ...erted in the test pressure outlet of the modulating adjustable gas valve and on the sealed chamber positive pressure test outlet The power data given in the table is obtained with intake exhaust pipe...

Page 24: ...ppm 123 71 161 84 165 80 Flue temperature at nominal heat output C 108 109 107 Flue temperature at minimum heat output C 87 91 91 Zeus 28 kW Gas nozzle diameter mm 1 35 0 79 0 79 Supply pressure mbar...

Page 25: ...loss at case with burner On Off 0 40 0 89 0 60 0 62 Heat loss at flue with burner On Off 5 50 0 03 5 50 0 01 Heating circuit max working pressure bar 3 3 Heating circuit max working temperature C 90...